Evidence map›Paper›PMID 41257914›Full record

ArticleBMC sports science, medicine & rehabilitation2025

Affordable fitness tracker step count, heart rate and calorie expenditure validation in controlled environment: a cross-sectional study.

Dhananjaya Sutanto, Billy C L So

Abstract read
In one paragraph

Article in BMC sports science, medicine & rehabilitation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Dhananjaya SutantoDepartment of Rehabilitation Sciences, Hong Kong Polytechnic University, Kowloon, Hong Kong, China.
Billy C L SoDepartment of Biomedical Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong, China. billy.so@polyu.edu.hk.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundObesity prevalence continues to increase globally, with increased physical activity considered as the most effective intervention. Fitness activity tracker have been shown to assist people increase their physical activity level, with increasing number of features and affordability over the past decade.

methodAn affordable fitness tracker, Archon Alive 001 was compared to Actigraph wGT3x-BT, with participants walking on treadmill at three, four, five and eight kilometers per hour (kph) and hand tally used as criterion measurement. Mean Absolute Percentage Error (MAPE) of Archon and Actigraph relative to hand tally at varying speeds, and related bivariate correlation were calculated, along with multivariate analysis of variance to assess the effect of speed and participant demographics on tracker MAPE. Polar OH1 heart rate monitor synchronized with PNOĒ metabolic analyzer was used to monitor heart rate and calorie expenditure. MAPE and correlation between PNOĒ and Archon calorie expenditure was calculated. Bland-Altman analysis and Intraclass Correlation Coefficient (ICC) was used to compare heart rate measurement between Polar and Archon.

resultsCompared to hand tally calculations, Archon step count was accurate, with average MAPE of 3.46%, and average correlation of r = 0.986, p < 0.001, while Actigraph average MAPE was 31.46%, with average correlation of r = 0.513, p = 0.001 at various speed. Age and speed had small effect on Archon’s accuracy. Sex had small effect, while speed had a large effect on Actigraph accuracy. Archon heart rate had Intraclass Correlation Coefficient (ICC) of 75.8%, with mean difference of -3.33 beats per minute (bpm) and 95% Limit of Agreement at -31.55 bpm to 24.90 bpm relative to Polar OH1. Archon total calorie expenditure output had 29.3% MAPE, and correlation r = 0.629, p < 0.001 relative to PNOĒ. DISCUSSION: Archon Alive demonstrated high accuracy in step counting, along with acceptable reliability and accuracy for heart rate and calorie expenditure measurements, making it sufficient for monitoring exercise intensity. Heart rate and calorie expenditure outputs were insufficiently accurate for clinical assessment.

Indexed as

CalorieFitness trackerHeart rateIntensityStep countValidity

Identifiers

PMID41257914
PMCPMC12628992

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.