ArticleScientific reports2025
Proof of concept for the usability of the IRRAMICE for proton preclinical radiobiological research by a traceable dosimetry evaluation.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
Abstract
Radiobiology relies on animal studies to demonstrate efficacy and safety of treatments. For proton-based studies in clinical settings, bespoke solutions, enabling animal irradiations without compromising health and safety regulations, need to be developed to facilitate the research. This study aims to demonstrate the usability of the IRRAMICE, a novel system with bespoke collimators to effectively treat small targets, within proton clinical facilities. Following a clinical workflow of planning CT, treatment plan design and delivery, a dosimetric evaluation of the IRRAMICE was conducted. Traceable absorbed dose was determined by measurements with (i) ion chamber, (ii) alanine pellets within a mouse phantom and a bespoke holder in the IRRAMICE, and (iii) Gafchromic film in the holder for a relative evaluation of the collimation system. Dose determined with alanine pellets in the mouse phantom were within 2% of the planned dose. The 2%/2 mm local gamma analysis of the dose distribution of the collimated beam spot determined by the film and the treatment planning system showed an average 98.3% passing rate. Through measurements in mouse phantoms, IRRAMICE demonstrated to be a suitable device for enabling the setup and delivery of treatment plans in a reliable and reproducible manner, to facilitate in vivo preclinical experiments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.