Evidence map›Paper›PMID 41254674›Full record

ArticleJournal of orthopaedic surgery and research2025

Application of a rapid and accurate safe-margin volume generation method in computer-assisted bone tumor resection surgery.

Yu Zhang, Daming Pang, Zhuoyu Li, Yang Sun, Weifeng Liu, Qing Zhang

Erratum issuedAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Yu ZhangSchool of Astronautics, Beihang University, Beijing, 102206, China.
Daming PangDepartment of Orthopaedic Oncology, Affiliated Beijing Jishuitan Hospital of Capital Medical University, Beijing, 100035, China.
Zhuoyu LiDepartment of Orthopaedic Oncology, Affiliated Beijing Jishuitan Hospital of Capital Medical University, Beijing, 100035, China.
Yang SunDepartment of Orthopaedic Oncology, Affiliated Beijing Jishuitan Hospital of Capital Medical University, Beijing, 100035, China.
Weifeng LiuDepartment of Orthopaedic Oncology, Affiliated Beijing Jishuitan Hospital of Capital Medical University, Beijing, 100035, China.
Qing ZhangDepartment of Orthopaedic Oncology, Affiliated Beijing Jishuitan Hospital of Capital Medical University, Beijing, 100035, China. jstzhangqing@vip.126.com.

Funding

Beijing Natural Science Foundation No. L252065the National Natural Science Foundation of China No. 62171017
6 · The paper itself

Abstract

introductionIn computer-assisted bone tumor resection, surgeons manually plan cut planes with a safe margin before surgery and follow them using navigation during osteotomy. However, manual planning is prone to error and often fails to ensure adequate margins. To address this, we propose an efficient method to rapidly and accurately generate a 3D safe-margin volume that uniformly extends the tumor by a safe margin.

methodsThe study was conducted on 20 patients (9 males, 11 females) between May 2018 and October 2023. The average age was 41.75 ± 14.72 years (14-66) and the tumor types were chondrosarcoma in 5 cases, giant cell tumor in 5 cases, osteosarcoma in 2 cases, chordoma in 2 cases, Ewing sarcoma in 2 cases, spindle cell sarcoma in 1 case, osteochondroma in 1 case, chondromyxoid fibroma in 1 case and peripheral nerve sheath tumor in 1 case. The quality of the generated safe-margin volumes were assessed by visual comparison outcomes, geometric errors and maximum absolute geometric errors, time costs and clinical outcomes.

resultsAll 20 patients were successfully followed up, with a mean follow-up duration of 42.30 ± 18.75 months (range: 3-86 months). The generated 3D safe-margin volumes were visually closer to the ground truth compared to those from the 3D morphological dilation and anisotropic distance transform methods. The method achieved a mean geometric error of approximately 0.10 mm, significantly lower than the dilation method (up to 10.00 mm) and the anisotropic method (about 1.00 mm). The average maximum absolute geometric error was 0.1818 mm, and statistical tests confirmed significant improvements (P-value < 0.01). The method also exhibited favorable computational efficiency, with an average runtime of 26.82 s, substantially faster than our previous point-based method (6.29 min) and acceptable for preoperative planning.

conclusionIn this study, we developed a fast and accurate safe-margin volume generation method by combining 3D image resampling with anisotropic distance transform. This method shows strong potential in clinical practice.

Indexed as

Bone NeoplasmsMargins of ExcisionOsteotomySurgery, Computer-AssistedAdolescentAdultAgedFemaleFollow-Up StudiesHumansImaging, Three-DimensionalMaleMiddle AgedTime FactorsYoung Adult3D anisotropic distance transform3D image resamplingComputer-assisted bone tumor resection surgerySafe-margin volume generation

Identifiers

PMID41254674
PMCPMC12625572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.