Comparison of log file-based and measurement-based QA for detecting MLC positional errors and evaluating dosimetric impacts of MLC defects.

Chul Hang Kim, Ki Mun Kang, Hoon Sik Choi

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chul Hang KimDepartment of Radiation Oncology, Gyeongsang National University School of Medicine, and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea.
Ki Mun KangDepartment of Radiation Oncology, Gyeongsang National University School of Medicine, and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea.
Hoon Sik ChoiDepartment of Radiation Oncology, Gyeongsang National University School of Medicine, and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea.ORCID https://orcid.org/0000-0003-0998-0685

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to compare the sensitivity of log file-based quality assurance (LF-QA) and measurement-based quality assurance (MB-QA) for detecting multileaf collimator (MLC) positional errors and to evaluate the dosimetric impacts of MLC mechanical drive train defects.

methodsMechanical degradation of the MLC was simulated on a TrueBeam STx system by inducing three defect types: T-nut surface wear (0.5-1.2 mm), drive screw thread wear, and motor degradation. MLC positioning accuracy was assessed using a rotational Picket Fence (PF) test, and the dosimetric impacts were evaluated on clinical breast intensity‑modulated radiation therapy (IMRT) and prostate volumetric‑modulated arc therapy (VMAT) plans. LF-QA and MB-QA were performed concurrently under identical delivery conditions. Gamma passing rates (GPRs) and dose-volume histogram (DVH) analyses were compared between baseline and defective deliveries.

resultsLF-QA detected positional deviations between baseline and defective conditions (<0.14 mm; p < 0.05) but consistently underestimated the extent of the induced defects. Correspondingly, LF-QA gamma analysis (GPRs ≈ 100%) and DVH metrics (∆D < 0.2%) showed no detectable dosimetric differences. MB-QA exhibited higher sensitivity to specific MLC defects, identifying localized fluence variations for T-nut surface wear, whereas no discernible differences were observed for drive screw thread wear or motor degradation. MB-QA gamma analysis revealed localized dose differences of up to 15% in breast IMRT and 7.4% in prostate VMAT. DVH analysis further demonstrated clinically relevant dose variations in organs at risk (OARs), including the contralateral breast (ΔD

conclusionLF-QA showed limited sensitivity to sub-millimeter MLC errors and did not capture clinically meaningful dosimetric deviations under mechanically degraded conditions. MB-QA enabled superior error detection and clinically relevant dosimetric verification. These findings indicate that LF-QA alone may be insufficient for patient-specific QA and that incorporating MB-QA is essential for ensuring reliable dosimetric verification.

Indexed as

Breast NeoplasmsParticle AcceleratorsPhantoms, ImagingProstatic NeoplasmsQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedFemaleHumansMaleOrgans at RiskRadiometryRadiotherapy Dosagelog file‐based QAmeasurement‐based QAmechanical wearMLC positional accuracy

Identifiers

PMID41253718
PMCPMC12626751

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.