Evidence map›Paper›PMID 41253297›Full record

ArticleAsian spine journal2026

Single-slice computed tomography-derived pedicle screw trajectory Hounsfield unit values predict screw loosening after lumbar fusion: a retrospective study in Japan.

Shuji Yamamoto, Satoshi Komatsubara, Takaaki Fujiki, Katsuya Mitamura, Masakazu Ishikawa

Abstract read
In one paragraph

Article in Asian spine journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shuji YamamotoDepartment of Orthopaedic Surgery, Faculty of Medicine, Kagawa University, Kagawa, Japan.
Satoshi KomatsubaraDepartment of Orthopaedic Surgery, Faculty of Medicine, Kagawa University, Kagawa, Japan.
Takaaki FujikiDepartment of Orthopaedic Surgery, Faculty of Medicine, Kagawa University, Kagawa, Japan.
Katsuya MitamuraDepartment of Radiology, Faculty of Medicine, Kagawa University, Kagawa, Japan.
Masakazu IshikawaDepartment of Orthopaedic Surgery, Faculty of Medicine, Kagawa University, Kagawa, Japan. ishikawa.masakazu@kagawa-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designRetrospective observational study. PURPOSE: This study aimed to determine the predictive utility of Hounsfield unit (HU) values, derived from single-slice computed tomography (CT) images, for identifying postoperative pedicle screw (PS) loosening in patients undergoing lumbar interbody fusion. The HU values were specifically measured along the planned PS trajectory. OVERVIEW OF LITERATURE: PS loosening is a frequent complication following spinal fusion surgery, particularly in individuals with compromised bone quality. Although prior research has explored the correlation between screw loosening and general vertebral HU values or bone mineral density, the specific predictive capability of a simple, single-slice measurement along the screw path remains a gap in the literature.

methodsWe retrospectively reviewed data from 47 patients (212 screws) who underwent lumbar interbody fusion between November 2020 and September 2022. Preoperative CT images were used to measure HU values in both the vertebral body and along the PS trajectories. Patients were then stratified into two groups based on the presence (L group, n=9) or absence (no-loosening [NL] group, n=38) of screw loosening identified on 1-year follow-up CT. Comparative analyses were conducted, followed by a receiver operating characteristic curve analysis to establish the optimal predictive HU cutoff.

resultsThe incidence of postoperative screw loosening was 11.8% (25/212). While no significant inter-group differences were observed regarding age, bone mineral density, or vertebral body HU values, the PS trajectory HU was significantly lower in the L group (111±40) compared to the NL group (157±74) (p <0.001). Receiver operating characteristic curve analysis identified an optimal HU cutoff of 123. The area under the curve was 0.7106, with an odds ratio of 3.18, sensitivity of 0.31, and specificity of 0.41.

conclusionsLower HU values measured along the PS trajectory using single-slice CT images were significantly associated with a higher risk of screw loosening. This straightforward method may serve as a valuable tool for identifying high-risk patients during the preoperative planning phase of spinal fusion surgery.

Indexed as

Bone mineral densityComputed tomographyLooseningPedicle screwsSpinal fusion

Identifiers

PMID41253297
PMCPMC13329228

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.