Evidence map›Paper›PMID 41250266›Full record

ArticleKnee surgery & related research2025

Does undersizing of the tibial component in unicompartmental knee arthroplasty increase the risk of fracture? A biomechanical study.

Julius Watrinet, Sabrina Sandriesser, Philipp Blum, Peter Augat, Marianne Hollensteiner, Rolf Schipp, Julian Fürmetz, Wolfgang Reng

Abstract read
In one paragraph

Article in Knee surgery & related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Julius WatrinetDepartment of Sports Traumatology and Arthroscopic Surgery, BG Unfallklinik Murnau, Murnau, Germany. Julius.watrinet@mri.tum.de.ORCID http://orcid.org/0000-0003-0578-4142
Sabrina SandriesserInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Philipp BlumDepartment of Sports Traumatology and Arthroscopic Surgery, BG Unfallklinik Murnau, Murnau, Germany.
Peter AugatInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Marianne HollensteinerInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Rolf SchippKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.
Julian FürmetzDepartment of Sports Traumatology and Arthroscopic Surgery, BG Unfallklinik Murnau, Murnau, Germany.
Wolfgang RengKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUnicompartmental knee arthroplasty (UKA) is a common treatment for medial osteoarthritis, providing faster recovery and better joint kinematics than total knee arthroplasty (TKA). However, periprosthetic tibial plateau fractures (TPF) remain a significant complication. Undersized tibial components, especially size AA, increase TPF risk. This study aims to examine the biomechanical relation between tibial implant size and the risk of periprosthetic fractures.

methodsA biomechanical study was conducted using 16 customized synthetic bone models to simulate the effects of tibial component sizing in UKA. Proximal tibial models with components of size A and size AA were subjected to axial loading, and the maximum load to failure and cycles to failure were measured for each size. Additionally, plastic axial deformation was calculated at the maximum load level of the weakest construct. Strain patterns were compared with clinically observed fracture lines reported in previous studies.

resultsSize AA had a significantly lower maximum load and cycles to failure compared with size A (1039 N ± 75 N and 9.336 ± 925 cycles versus 1140 N ± 83 N and 8.326 ± 759 cycles, p = 0.031). The strain patterns were consistent with those observed in clinical studies, showing a wedge-shaped distribution from the posteromedial to the anteromedial tibial plateau. Plastic deformation was less than 0.6 mm across all specimens, with no significant difference in axial displacement between the two groups (p = 0.64).

conclusionUndersizing the tibial component reduces load-bearing capacity of the tibial plateau and thereby increases the risk of periprosthetic fractures. Precise implant sizing by correct sagittal resection is essential to minimize the risk of fracture in UKA. EXPERIMENTAL STUDY: Type V.

Indexed as

Biomechanical testingOxfordPeriprosthetic fracturesTibial component sizingUnicompartmental knee arthroplasty

Identifiers

PMID41250266
PMCPMC12625240

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials