Experimental verification and comparative analysis of peak expiratory flow measuring devices.

Concepción Paz, Eduardo Suárez, Alberto Fernández-Villar, Elena Puga

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Concepción PazCINTECX, University of Vigo, Campus Universitario Lagoas-Marcosende, Vigo, 36310, Spain. cpaz@uvigo.gal.ORCID http://orcid.org/0000-0001-6831-5322
Eduardo SuárezCINTECX, University of Vigo, Campus Universitario Lagoas-Marcosende, Vigo, 36310, Spain.ORCID http://orcid.org/0000-0002-9920-3291
Alberto Fernández-VillarService of Pneumology, University Hospital Complex of Vigo, Sergas, Vigo, Spain.ORCID http://orcid.org/0000-0001-7407-5249
Elena PugaCINTECX, University of Vigo, Campus Universitario Lagoas-Marcosende, Vigo, 36310, Spain.ORCID http://orcid.org/0009-0008-9720-4064

Funding

Fundación Pública Galega de Investigación Biomédica Galicia Sur. Funding for open access charge
6 · The paper itself

Abstract

This study presents a comprehensive benchmarking of six commercially available peak expiratory flow meters (PFMs), using a precise experimental spirometric test bench. Eight peak expiratory flows (PEF) ranging from 59.40 to 688.80 L/min at three frequencies, were systematically applied to each device. Through a series of controlled tests, the devices' precision, accuracy, linearity, inter-device variability, and dynamic response were meticulously evaluated across their full measurement range. Results reveal distinct performance characteristics among models, with some demonstrating high precision and accuracy in intermediate flow ranges, whereas others exhibited significant deviations at lower or higher flows. Inter-device variability was minimal except for specific models at lower flow rates. Dynamic response at varying frequencies indicated negligible impact on device readings. This benchmarking provides valuable insights for clinicians and researchers selecting appropriate PFMs for respiratory assessments.

Indexed as

SpirometryHumansPeak Expiratory Flow RateReproducibility of ResultsBenchmarkingPeak expiratory flow meterPEFRespiratory measurementSpirometry