ArticleCardiovascular intervention and therapeutics2026
Hemodynamic implications of direct sheath insertion through VA-ECMO arterial cannula: an In-Vitro model.
Article in Cardiovascular intervention and therapeutics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In patients supported by venoarterial extracorporeal membrane oxygenation (VA-ECMO), concomitant percutaneous procedures are often limited by difficulty obtaining vascular access. Although prior case reports have described using the ECMO arterial cannula as an access site, the hemodynamic implications are unknown. This in-vitro study examined the effect of direct catheter sheath insertion through the VA-ECMO arterial cannula on circuit hemodynamics. An ECMO circuit was constructed in a water-based bench model with arterial cannula size of 13.5, 15, and 16.5 Fr. We measured flow and pressure changes with the direct Seldinger insertion of 4, 5, 6, and 7 Fr sheaths and catheter into the arterial ECMO cannula, simulating concomitant catheter-based interventions. We demonstrated that sheath insertion consistently reduced circuit flow in a size-dependent manner, requiring higher pump speeds to maintain comparable flow. At the maximum pump speed (3000 rpm), the largest cannula (16.5 Fr) maintained flow rates > 3.0 L/min across all sheath sizes tested, whereas the 15 Fr cannula achieved this only with 4-6 Fr sheaths and the 13.5 Fr cannula only with a 4 Fr sheath. Our findings suggest that certain combinations of ECMO cannula and sheath sizes can preserve adequate perfusion, supporting the feasibility of this simple, reproducible technique under carefully selected conditions. This study provides the first evaluation of flow dynamics for this procedure in a standardized setting. Further studies are warranted to confirm our findings.
Indexed as
Identifiers
41249766What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.