Evidence map›Paper›PMID 41249233›Full record

ArticleScientific reports2025

Enhancing microgrid resilience through integrated grid-forming and grid-following inverter strategies for solar PV battery control and fault ride-through.

Md Ismail Hossain, Hasanur Zaman Anonto, Abu Shufian, Bishwajit Banik Pathik, Mohammad Abdul Mannan, Abdur Rashid, Parag Biswas

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Md Ismail HossainDepartment of Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh.ORCID http://orcid.org/0009-0000-2725-1860
Hasanur Zaman AnontoDepartment of Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh.ORCID http://orcid.org/0009-0000-6929-501X
Abu ShufianDepartment of Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh. shufian.eee@aiub.edu.ORCID http://orcid.org/0000-0001-6914-0966
Bishwajit Banik PathikDepartment of Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh.ORCID http://orcid.org/0000-0002-0437-8778
Mohammad Abdul MannanDepartment of Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh.ORCID http://orcid.org/0000-0002-7257-1369
Abdur RashidDepartment of Electrical and Electronic Engineering, Daffodil International University, Dhaka, Bangladesh.ORCID http://orcid.org/0009-0006-3145-6707
Parag BiswasDepartment of Electrical and Electronic Engineering, Daffodil International University, Dhaka, Bangladesh.ORCID http://orcid.org/0009-0001-0599-6201

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigates the integration of a Grid-Forming (GFM) Battery Energy Storage System (BESS) to enhance the stability of microgrids in the presence of high renewable energy penetration. The proposed GFM inverter, combined with BESS, significantly improves fault resiliency and oscillation stability compared to traditional Grid-Following (GFL) inverters. The GFM inverter enables fault ride-through (FRT), maintaining operational stability during grid faults with voltage recovery within 300 ms and frequency deviations limited to ± 0.5 Hz. The GFM-controlled system stabilized within 1 s during a 50% solar irradiance drop, supplying reactive power and inertial support, while the GFL inverter struggled to stabilize under a Short Circuit Ratio (SCR) of 0.423, leading to large voltage and frequency deviations. Additionally, during a 46% increase in load demand, the BESS under GFM control immediately compensated for the real power imbalance, demonstrating the crucial role of energy storage in improving microgrid stability. In contrast, the GFL inverter failed to stabilize under similar conditions. Simulation results using MATLAB/Simulink confirmed that the GFM inverter restored microgrid stability more effectively, with faster fault recovery and improved voltage regulation compared to GFL inverters. The implementation of an Energy Management System (EMS) optimized power flow between the PV, BESS, and grid, enhancing system efficiency and participation in energy markets. These findings validate the potential of GFM inverters, supported by advanced control strategies, to provide reliable, efficient, and sustainable microgrid operations, indicating their practical viability in future energy networks.

Indexed as

BESSDroop controlGrid following inverterGrid forming inverterMicrogridPLLPQ controlPV energy

Identifiers

PMID41249233
PMCPMC12624142

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.