Evidence map›Paper›PMID 41247503›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2025

Systematic review and meta-analysis of side effects and severe complications caused by intracoronary pressure measurement.

J Michael Altstidl, Luise Gaede, Merve Günes-Altan, Mohamed Marwan, Stephan Achenbach, Monique Tröbs

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

J Michael AltstidlDepartment of Medicine 2, Cardiology and Angiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Ulmenweg 18, 91054, Erlangen, Germany. michael.altstidl@fau.de.ORCID http://orcid.org/0000-0002-7395-8151
Luise GaedeDepartment of Medicine 2, Cardiology and Angiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Ulmenweg 18, 91054, Erlangen, Germany.ORCID http://orcid.org/0000-0002-9678-908X
Merve Günes-AltanDepartment of Medicine 2, Cardiology and Angiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Ulmenweg 18, 91054, Erlangen, Germany.ORCID http://orcid.org/0009-0005-3770-6562
Mohamed MarwanDepartment of Medicine 2, Cardiology and Angiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Ulmenweg 18, 91054, Erlangen, Germany.ORCID http://orcid.org/0000-0001-8759-4101
Stephan AchenbachDepartment of Medicine 2, Cardiology and Angiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Ulmenweg 18, 91054, Erlangen, Germany.ORCID http://orcid.org/0000-0002-7596-095X
Monique TröbsDepartment of Medicine 2, Cardiology and Angiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Ulmenweg 18, 91054, Erlangen, Germany.ORCID http://orcid.org/0000-0002-5661-1017

Funding

State of Bavaria ER-MIKKIState of Bavaria LSM-2007-0002
6 · The paper itself

Abstract

backgroundEven though current guidelines recommend intracoronary pressure measurement such as fractional flow reserve (FFR) to assess the hemodynamic relevance of angiographically intermediate stenoses, little is known about the incidence of side effects and there is no large-scale data on complications of intracoronary pressure measurements.

methodsThe PubMed database was searched for large multicenter trials and registries of patients undergoing intracoronary pressure measurement. Publications were screened regarding side effects and complications. Data on chest pain, dyspnea, arrhythmia, bronchospasm, hypotension, nausea, and coronary artery injury were collected and analyzed.

resultsA total of 19 studies with 22,768 patients were included. FFR measurement was reported to cause chest pain in 29% (95% CI 2-91%), dyspnea in 20%, hypotension in 0.8% (95% CI 0.3-2.1%), vomiting or nausea in 0.9%, and bronchospasm in 0.2% (95% CI 0.0-0.7%) of patients. Arrhythmia occurred in 3% (95% CI 1-16%), more specifically atrioventricular block in 2% (95% CI 0-14%) and ventricular arrhythmia in 0.1% (95% CI 0.1-0.3%), during intracoronary pressure measurement. The pressure wire was reported to have caused coronary artery dissection in 0.2% (95% CI 0.1-0.5%), coronary artery occlusion in 0.2% (95% CI 0.1-0.3%), and coronary artery perforation in 0.1% of patients. Coronary artery injury required revascularization on rare occasions and was fatal in two patients.

conclusionsTransient side effects due to adenosine administration are common when FFR is measured. While infrequent, coronary artery injury caused by the pressure wire occurs in 0.5% of patients and is a relevant complication of intracoronary pressure measurement.

Indexed as

ComplicationFractional flow reserve (FFR)Instantaneous wave-free ratio (iFR)Intracoronary pressure measurementMeta-analysisSide effect

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.