Evidence map›Paper›PMID 41247473›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2026

Intravitreal injection delivered volume under different environmental and training conditions.

Mateus Lins Dos Santos, Lucas Andrade Santos, Alexandre Lima Cardoso, Lydianne Lumack Monte Agra, Jorge Artur Peçanha Miranda Coelho, Gustavo Barreto Melo

Abstract read
PubMed Publisher
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mateus Lins Dos SantosHospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil.
Lucas Andrade SantosHospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil.
Alexandre Lima CardosoHospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil.
Lydianne Lumack Monte AgraHospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil.
Jorge Artur Peçanha Miranda CoelhoFederal University of Alagoas, Maceió, AL, Brazil.
Gustavo Barreto MeloHospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil. gustavobmelo@yahoo.com.br.ORCID http://orcid.org/0000-0001-5765-2008

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the accuracy of intravitreal injection (IVI) volumes under varying environmental conditions and operator training levels.

methodsThree syringe models (Becton-Dickinson Plastipak 1mL, Aflibercept Prefilled Syringe, and Zero Residual Silicone Oil-Free 0.2 mL) were tested with 30G needles. Distilled water was drawn against different background colors (beige, black, blue, green, and white) by a single trained operator. Later, three different operators (a medical student, an ophthalmology resident, and a vitreoretinal surgeon) performed the injections under three training conditions (no prior training, after proper training, and forced plunger depression). The 50 µl of water were expelled into Eppendorf tubes and both syringes and tubes were weighed before and after injection. The main parameters measured were the effective delivered volume and residual volume.

resultsSignificant differences were found among syringes (p < 0.001). Operator proficiency (p = 0.007) and training status (p < 0.001) also influenced volume accuracy. Post-hoc analysis revealed significant differences between clear green and black (p = 0.007), and between beige and black backgrounds (p = 0.008).

conclusionsOur study revealed significant variations in IVI volumes, influenced by syringe type, operator proficiency, and background color. These findings emphasize the need to consider materials and techniques for precision in IVI.

Indexed as

Clinical CompetenceEducation, Medical, GraduateInternship and ResidencyIntravitreal InjectionsOphthalmologyReceptors, Vascular Endothelial Growth FactorRecombinant Fusion ProteinsSyringesAngiogenesis InhibitorsEquipment DesignHumansVascular Endothelial Growth Factor AafliberceptAngiogenesis InhibitorsReceptors, Vascular Endothelial Growth FactorRecombinant Fusion ProteinsVascular Endothelial Growth Factor AIntravitreal drug administrationIntravitreal injectionsMedical educationSyringes

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.