Evidence map›Paper›PMID 41245881›Full record

ArticleJournal of medical signals and sensors2025

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System Versus BEAMnrc Simulation in Nasopharyngeal Carcinoma: A Phantom study.

Seyed Salman Zakariaee, Fereshteh Koosha, Mostafa Robatjazi, Hamed Rezaeejam, Mikaeil Molazadeh

Abstract read
In one paragraph

Article in Journal of medical signals and sensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Seyed Salman ZakariaeeDepartment of Medical Physics, Faculty of Paramedical Sciences, Ilam University of Medical Sciences, Ilam, Iran.
Fereshteh KooshaDepartment of Radiology Technology, Faculty of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Mostafa RobatjaziDepartment of Medical Physics and Radiological Sciences, Sabzevar University of Medical Sciences, Sabzevar, Iran.
Hamed RezaeejamDepartment of Radiology Technology, School of Paramedical Sciences, Zanjan University of Medical Sciences, Zanjan, Iran.
Mikaeil MolazadehMedical Radiation Sciences Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate dose calculations in radiotherapy are essential, especially in complex anatomical areas such as the nasopharynx, where heterogeneous tissue compositions can greatly influence treatment outcomes. This study assesses the accuracy of the full scatter convolution (FSC) algorithm within the TiGRT treatment planning system by comparing it to the BEAMnrc Monte Carlo (MC) simulation using a head phantom. Methods: EBT3 film was strategically placed in the nasopharyngeal region to enable direct comparisons between experimental results and those derived from the FSC and MC methods. Various metrics, including the dose difference index, two-dimensional gamma index, and horizontal and vertical dose profiles, were employed for the analysis. The heterogeneous regions were classified into bone, air, and soft-tissue components. For dosimetric evaluation, the irradiated areas were segmented into four regions based on isodose values: Field region (FR), irradiated region (IR), penumbra region (PR), and out-of-FR (OOFR). Results: The greatest computational discrepancies observed between the FSC algorithm and MC simulations in the air region of the FR were -5.12% ± 1.10% and 1.93% ± 1.45%, respectively. Notable underestimations occurred in the air and soft-tissue regions of the IR, PR, and OOFR when using the FSC algorithm, with a minimum discrepancy of -9.33% ± 5.51% and a maximum of -77.28% ± 8.19%. Conversely, doses calculated for the bone region were overestimated by 53.64% ± 5.65%. In comparison, the MC calculations in the IR region revealed discrepancies of 1.90% ± 1.55% (air), including a maximum underestimation of -8.82% ± 1.18% in the bone area within the PR. The gamma pass rates for different tissue types under local and global modes, using 3%-3 mm gamma criteria, demonstrate that the MC method consistently outperformed the TiGRT method across all tissue types, especially in the air (99.9%) and bone (99.8%) regions. Conclusions: The findings reveal that the FSC algorithm tends to underestimate doses in soft tissue and air while overestimating doses in bone. In contrast, there was excellent agreement between MC calculations and experimental measurements, highlighting the FSC algorithm's lower consistency.

Indexed as

BEAMnrcEBT3 filmgamma indexnasopharyngeal carcinomaTiGRT treatment planning system

Identifiers

PMID41245881
PMCPMC12617975

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.