ArticleFrontiers in bioengineering and biotechnology2025
Breaking the treatment dilemma of Schatzker IV fractures: finite element analysis validates hybrid single-plate with tension screw fixation for synergistic optimization of stability and minimally invasive outcomes.
Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: The core challenge in treating Schatzker type IV tibial plateau fractures lies in balancing mechanical stability with minimally invasive techniques. Traditional double-plate fixation carries a high risk of soft tissue complications, while single-plate fixation provides insufficient mechanical strength. This study aims to systematically evaluate and compare the biomechanical performance of five internal fixation strategies for Schatzker type IV-A and IV-B fractures using finite element analysis (FEA), exploring whether optimized fixation configurations can achieve synergy between minimally invasive treatment and stability. Method: Three-dimensional models of Schatzker type IV-A and IV-B fractures were constructed based on CT data from a 43-year-old male patient. Soft tissue models including ligaments and menisci were established. Five fixation methods were simulated: isolated medial plate (IMLP), medial plate with two posteromedial tension screws (IMLP + 2PMS), medial plate with two lateral tension screws (IMLP + 2LTS), posteromedial and medial double plating (PMP + MLP), and medial and lateral double plating (MLDP). Axial loads from 300 N to 2400 N were applied to simulate conditions ranging from standing to vigorous activity. Implant stress, tibial shaft stress, and fracture fragment micromotion were quantified. Result: Under a 1200 N load, hybrid fixation modes (IMLP + 2PMS and IMLP + 2LTS) demonstrated superior biomechanical performance. They exhibited the lowest peak implant stress (Type IV-A: IMLP + 2PMS 124.21 MPa; Type IV-B: IMLP + 2PMS 115.64 MPa), significantly better than the IMLP group (∼248 MPa), and comparable or superior to double-plate fixation groups (MLDP, PMP + MLP). While fracture fragment displacement showed no significant differences across all fixation methods, IMLP + 2PMS effectively reduced stress in type IV-B fragments. Regarding stress distribution in the tibial shaft, hybrid fixation provided a more uniform and physiological pattern compared to double-plate fixation. The results indicate differential responses to fixation strategies between type IV-A and IV-B fractures, with type IV-B deriving more pronounced benefits from posteromedial tension screws. Conclusion: The hybrid fixation configuration of a "medial plate combined with tension screws" represents a biomechanically optimal solution for treating Schatzker type IV-A and IV-B fractures. It provides stability comparable to double-plate fixation while significantly reducing implant stress concentration and the "stress-shielding" effect through a minimally invasive approach, achieving a synergy between minimal invasiveness and stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.