Mechanical optimization of plate-screw interfaces in variable-angle locking systems: a parametric study.

Chen-Chiang Lin, Shun-Ping Wang, Kun-Jhih Lin, Ming-Hsien Hu

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chen-Chiang LinDepartment of Orthopedics, National Taiwan University Hospital Yunlin Branch, Yunlin, Taiwan.
Shun-Ping WangDepartment of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan.
Kun-Jhih LinTechnology Translation Center for Medical Device, Chung Yuan Christian University, Taoyuan, Taiwan.
Ming-Hsien HuDepartment of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Variable-angle locking systems offer increased surgical flexibility by permitting off-axis screw insertion, with some designs allowing angulation up to 15°. However, clinical challenges such as screw loosening and insufficient mechanical stability data persist. This study aims to evaluate the impact of different plate hole design parameters on the locking strength of plate-screw head interface under various screw insertion angles, providing insights to optimize VALS performance in fracture fixation. Methods: Variable-angle locking system with Point-Loading Thread-In mechanism was designed for investigation. Variations in locking hole design were evaluated based on slot size (1.3 mm vs. 1.5 mm), number of thread columns (three vs. four), and cone angle (20° vs. 22°). A total of eight distinct design groups were included for analysis. The screws, inserted at different inclinations (0°-15°), and locked at 0.8 Nm were subjected to a cantilever load-to-failure test. Ultimate bending moment at the screw-head interface and failure mode of the locking mechanism were determined. Results: The results exhibited a decrease in bending strength with increasing screw angulation in both three- and four-thread designs, with all groups exceeding 1 Nm at 0° but falling below 1 Nm at 15°. The highest bending moment was 1.46 Nm in the three-thread-column design at 0°, compared with 1.32 Nm in the four-thread-column design. At 15° screw angulation, the highest moments were 0.92 Nm and 0.90 Nm for the three-thread and four-thread designs, respectively. The plate hole with 1.3 mm slot, three thread column and 22° cone design showed higher bending moment than all other designs at each insertion angles. Discussion: Plate hole design-specifically slot size, thread number, and cone angle-significantly influences locking strength. The optimal design (3 slots, 1.3 mm, 22°) offers superior mechanical stability, guiding device optimization.

Indexed as

angulationbending momentbiomechanical studybone platevariable angle locking

Identifiers

PMID41245634
PMCPMC12611835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.