Evidence map›Paper›PMID 41245573›Full record

ArticleACS materials Au2025

Ultrahigh-Response Humidity Sensor Arrays Based on a Graphene/Polymer Composite for Contactless Gesture Monitoring.

Jinqi Hou, Xigang Zhu, Lu Zheng, Weiwei Li, Jiuwei Gao, He Huang, Yue Li, Manzhang Xu, Xuewen Wang

Abstract read
In one paragraph

Article in ACS materials Au, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jinqi HouState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
Xigang ZhuState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
Lu ZhengState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
Weiwei LiState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
Jiuwei GaoState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
He HuangState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
Yue LiState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.
Manzhang XuState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.ORCID https://orcid.org/0000-0001-6752-5299
Xuewen WangState Key Laboratory of Flexible Electronics (LoFE) & Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.ORCID https://orcid.org/0000-0002-9689-6678

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Flexible humidity sensors have attracted widespread attention for their potential applications in telemedicine, motion detection, etc. Compared with conventional humidity sensors, flexible humidity sensors have advantages in flexibility, integration, and portability. However, reported flexible humidity sensors usually suffer from a low response, complex manufacturing processes, and poor stability. We fabricate a humidity sensor using a graphene/polymer composite as the sensitive material with a focus on improving the response and simplifying the manufacturing process. Then, we optimize the performance of the prepared flexible sensor by component design. The prepared flexible humidity sensor has a response of 1123%, and response and recovery times of 61.1/92.0 s, respectively, showing excellent humidity sensing performance. The human respiration, skin humidity field, and environmental humidity detection applications are successfully realized by the humidity sensor. Besides, the contactless gesture monitoring is accomplished by the humidity sensor array, demonstrating the potential for further development into healthcare and contactless human-machine interaction.

Indexed as

contactless gesture monitoringflexible electronicsflexible humidity sensorgraphene/polymer compositerespiratory detection

Identifiers

PMID41245573
PMCPMC12616429

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.