Evidence map›Paper›PMID 41244407›Full record

ArticleACS omega2025

Fabrication of Disposable Thin-Film Electrodes via Shadow Mask Technique for Sensitive Point-of-Care Detection of C‑Reactive Protein, a Sepsis Biomarker.

Mahsa Kalantar, Ali Hossein Rezayan, Hassan Hajghassem, Reza Askari Moghadam, Hedayatollah Ghourchian, Amir Mohamadsharifi

Abstract read
In one paragraph

Article in ACS omega, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mahsa KalantarSchool of Life Science Engineering, College of Interdisciplinary Science and Technology, University of Tehran, Tehran 1439957131, Iran.ORCID https://orcid.org/0000-0002-7861-6521
Ali Hossein RezayanSchool of Life Science Engineering, College of Interdisciplinary Science and Technology, University of Tehran, Tehran 1439957131, Iran.ORCID https://orcid.org/0000-0003-0414-0062
Hassan HajghassemSchool of Intelligent Systems, College of Interdisciplinary Science and Technology, University of Tehran, Tehran 1439957131, Iran.ORCID https://orcid.org/0000-0001-8950-8481
Reza Askari MoghadamSorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, LIB, F-75006 Paris, France.
Hedayatollah GhourchianLaboratory of Bioanalysis, Institute of Biochemistry & Biophysics, University of Tehran, 13145-1384 Tehran, Iran.
Amir MohamadsharifiSchool of Intelligent Systems, College of Interdisciplinary Science and Technology, University of Tehran, Tehran 1439957131, Iran.ORCID https://orcid.org/0000-0002-3556-2391

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Point-of-care testing for sepsis refers to diagnostic technologies that rapidly and effectively detect sepsis using specific biomarkers. The development of thin-film electrodes (TFEs) for biosensing applications has been frequently reported in recent years. Notably, TFEs have been employed to develop biosensors for C-reactive protein (CRP), a key biomarker of sepsis. This study presents a straightforward and rapid method for fabricating TFEs on substrates using a shadow mask technique. The process employs commercially available polyvinyl chloride sticker film, serving as a disposable shadow mask, to create a three-electrode system (working electrode (WE), counter electrode (CE), and reference electrode (RE) on a poly-(methyl methacrylate) substrate. The sequential deposition of 20 nm of titanium (Ti) and 120 nm of gold (Au) formed the WE and CE, while the RE was fabricated by depositing titanium and silver (Ag). The fabricated TFEs were characterized by field emission scanning electron microscopy, atomic force microscopy, and energy-dispersive X-ray spectroscopy analyses, revealing notable differences in surface morphology and elemental composition. A specific aptamer for the CRP biomarker is immobilized on the surface of a TFE. The electrochemical biosensor demonstrated a linear range of 0.02-0.9 ng/mL and a limit of detection of 6.5 pg/mL, indicating high sensitivity for detecting the CRP biomarker.

Identifiers

PMID41244407
PMCPMC12613123

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.