Evidence map›Paper›PMID 41244139›Full record

ArticleEJVES vascular forum2025

Objective Perfusion Assessment With Near Infrared Fluorescence for Guidance of Bowel Resection Margins Following Superior Mesenteric Artery Thrombosis: A Case Report.

Roderick C Peul, Floris P Tange, Joost R van der Vorst

Abstract readCase Reports
In one paragraph

Article in EJVES vascular forum, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Roderick C PeulDepartment of Surgery, Leiden University Medical Centre, Leiden, the Netherlands.
Floris P TangeDepartment of Surgery, Leiden University Medical Centre, Leiden, the Netherlands.
Joost R van der VorstDepartment of Surgery, Leiden University Medical Centre, Leiden, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Acute occlusion of the superior mesenteric artery (SMA) results in extensive bowel ischaemia, with mortality rates approaching 70%. Management involves acute revascularisation, typically via embolectomy, and intra-operative evaluation to distinguish viable from non-viable intestinal tissue. Near infrared fluorescence (NIRF) imaging with indocyanine green (ICG) enables real time, minimally invasive assessment of tissue perfusion. This case report illustrates the usability of NIRF imaging to guide surgical decision making for bowel preservation and patient survival in a clinical situation where research is limited. Report: A 40 year old male presented, in June 2023, with severe postprandial abdominal pain. Imaging revealed a non-occlusive thrombus in the SMA, which together with clinical deterioration resulted in an emergency embolectomy. Intra-operative NIRF imaging with ICG identified malperfusion of a jejunal segment. A second NIRF assessment post-embolectomy confirmed persistent malperfusion, guiding resection with a primary anastomosis. Quantitative fluorescence analysis confirmed the intra-operative findings of malperfusion and demonstrated potential utility for objective perfusion assessment to resect non-viable tissue and limit viable tissue resection. The patient recovered uneventfully and was discharged on post-operative day five. Discussion: This case highlights the use of NIRF imaging as a safe, low cost technique for evaluating bowel perfusion during SMA embolectomy. By selecting adjacent regions of interest, surgeons can compare objective perfusion curves intra-operatively and select optimal anastomosis sites. Quantified parameters further aid decision making, showing clear percentage differences in perfusion between viable and ischaemic tissue. Although standardised cut off values are lacking, combining clinical evaluation, subjective assessment, and quantitative data offers a patient tailored approach to optimising resection margins.

Indexed as

EmbolectomyIndocyanine greenNear infrared fluorescence imagingPerfusion assessmentQuantificationSuperior mesenteric artery

Identifiers

PMID41244139
PMCPMC12615766

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.