Assessment of Intraocular Pressure Measurement Between Goldmann Applanation Tonometer and Portable Non-Contact Tonometer (TH1U).
Article in Clinical ophthalmology (Auckland, N.Z.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To investigate the consistency of intraocular pressure measurements between portable non-contact tonometer (PNCT) and Goldmann applanation tonometer (GAT). Patients and Methods: A total of 81 participants (150 eyes) who were aged ≥18 years and had no history of eye surgery within 3 months were recruited. Eyes were categorized into three IOP groups: 7-16 mmHg (n = 50, 33.3%), >16 to <23 mmHg (n = 50, 33.3%), and ≥23 mmHg (n = 50, 33.3%). All participants underwent PNCT and GAT intraocular pressure measurements in sequence, and central corneal thickness (CCT) was recorded. Pearson correlation analysis was used to evaluate the correlation between PNCT and GAT intraocular pressure results, and the intraclass correlation coefficient (ICC) and Bland-Altman method were used to evaluate the consistency. The effect of CCT on intraocular pressure measurement was further analyzed. Results: A total of 81 subjects (150 eyes) were included. The mean intraocular pressure measured by GAT and PNCT was 21.1±7.8mmHg and 21.4±7.5mmHg, respectively, with no significant difference between the two (P>0.05). The IOP values measured by the two devices were highly positively correlated (r²=0.934, P<0.001), with an ICC of 0.933, indicating good consistency. Bland-Altman analysis showed that the mean difference between GAT and PNCT was -0.2±2.8mmHg, the limits of agreement (LoA) was +5.3 to -5.8mmHg, and 93.33% of the differences fell within ±5mmHg. CCT was significantly positively correlated with the IOP values measured by both devices, but did not significantly impact the agreement between them. Conclusion: PNCT demonstrates high consistency with GAT and offers a reliable alternative for IOP monitoring. Its portability, non-contact operation, and automatic measurement function make it particularly suitable for home-based and long-term glaucoma management.