Hydraulic In Vitro Characterization of MR-Conditional Blood Pumps.

Dominik T Schulte, Marcel Renggli, Henning Richter, Francesca Del Chicca, Michael Hofmann, Martin O Schmiady, Marianne Schmid Daners

Abstract read
In one paragraph

Article in Artificial organs, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. PreliminaryFrontiers in medical technology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dominik T SchulteInstitute for Dynamic Systems and Control, ETH Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-0188-6726
Marcel RenggliProduct Development Group Zurich, ETH Zurich, Zurich, Switzerland.
Henning RichterDiagnostic Imaging Research Unit, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Francesca Del ChiccaDiagnostic Imaging Research Unit, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-8996-1961
Michael HofmannCenter for Cardiac Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Martin O SchmiadyCenter for Cardiac Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Marianne Schmid DanersInstitute for Dynamic Systems and Control, ETH Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-6411-8871

Funding

Innosuisse - Schweizerische Agentur für Innovationsförderung 56642.1 IP-LS
6 · The paper itself

Abstract

backgroundMany cardiac surgical procedures use cardiopulmonary bypass (CPB), which in neonates requires the heart-lung machine (HLM) to be positioned close to the patient due to their small circulating blood volume. The absence of an MR-compatible blood pump to be used in CPB remains a key challenge for studying perioperative brain injury mechanisms in this high-risk group. This study aims to take the first step toward MR-conditional HLMs by developing hardware, verifying pump hydraulics, and ensuring MR compatibility.

methodsThis study presents three MR-conditional blood pump prototypes: a roller pump, a non-occlusive roller pump, and a centrifugal pump. MR compatibility was assessed by monitoring for imaging interference during scanning. Hydraulic performance was evaluated with pressure-flow diagrams using a mock circulation test bench.

resultsNone of the prototypes interfered with MR imaging, and although SNR was reduced by -8.43% ± 7.96%, image quality remained sufficient for reliable assessment of relevant brain regions. Roller and non-occlusive pumps maintained stable flow across pressure heads, with reductions of -4.46 ± 8.02 and -119.33 ± 18.22 mL/min, respectively. The centrifugal pump exhibited pressure-dependent performance (slope -2.21 ± 0.45 mmHg/[L/min]). All pumps generated non-pulsatile flow (SHE < 1000 erg/cm

conclusionAll three pumps meet basic MR-conditionality and flow requirements, supporting their potential for use in MRI-guided studies during neonatal cardiac surgery.

Indexed as

Cardiopulmonary BypassHeart-Assist DevicesHeart-Lung MachineMagnetic Resonance ImagingEquipment DesignHumansblood pumpcardiopulmonary bypassextracorporeal membrane oxygenationin vitro testingMR‐conditional

Identifiers

PMID41243721
PMCPMC13090745

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.