Evidence map›Paper›PMID 41242740›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2026

Effect of the Modified Look-Locker Inversion Recovery Sampling Scheme on Accuracy and Heart Rate Variability in Myocardial T1 Mapping.

Yuta Endo, Keita Fukushima, Akihito Nakanishi, Kenichi Yokoyama

Abstract read
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yuta EndoDepartment of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, Mitaka, Tokyo, Japan.
Keita FukushimaDepartment of Radiology, Kyorin University Hospital, Mitaka, Tokyo, Japan.
Akihito NakanishiDepartment of Radiology, Kyorin University Hospital, Mitaka, Tokyo, Japan.
Kenichi YokoyamaDepartment of Radiology, Faculty of Medicine, Kyorin University, Mitaka, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to clarify the accuracy and variability of heart rate variability effects on T1 relaxation time values acquired using different sampling schemes of the modified Look-Locker inversion recovery (MOLLI) method. Five MOLLI sampling schemes-5(3)3, 5s(3s)3s, 4(1)3(1)2, 4s(1s)3s(1s)2s, and 3(3)3(3)5-were compared using a simulated electrocardiogram signal in a phantom experiment. The 5(3)3 and 5s(3s)3s schemes demonstrated high accuracy across the range of native and contrast-enhanced T1 values, with correlation coefficients exceeding 0.95 compared with the reference T1. Regarding heart rate variability, the 5(3)3 scheme showed minimal variation in the measured value across different heart rates, regardless of the T1 value, with an error rate below 6% relative to the reference T1. Therefore, the 5(3)3 scheme can achieve highly accurate measurements over a wide T1 range and is robust against heart rate variability.

Indexed as

accuracyheart rate variabilitymodified Look–Locker inversion recoverymyocardial T1 mappingsampling scheme

Identifiers

PMID41242740
PMCPMC13247636

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.