Evidence map›Paper›PMID 41241755›Full record

ArticleBMC chemistry2025

Point-of-care nano zinc oxide carbon paste sensor for non-invasive determination of clozapine in saliva samples.

Mariam O Abd El-Aziz, Amr M Bekhet, Hany H Monir, Sameh E Younis, M Nebsen, Ahmed H Nadim

Abstract read
In one paragraph

Article in BMC chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mariam O Abd El-AzizDepartment of Pharmaceutical Chemistry, Faculty of Pharmacy, Pharos University in Alexandria;, Canal El Mahmoudia Street, Beside Green Plaza Complex 21648, Alexandria, Egypt. mariam.omar@pua.edu.eg.
Amr M BekhetPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo ET-11562, Egypt.
Hany H MonirPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo ET-11562, Egypt. Hany.hunter@pharma.cu.edu.eg.
Sameh E YounisDepartment of Pharmaceutical Chemistry, Faculty of Pharmacy, Pharos University in Alexandria;, Canal El Mahmoudia Street, Beside Green Plaza Complex 21648, Alexandria, Egypt.
M NebsenPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo ET-11562, Egypt.
Ahmed H NadimPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo ET-11562, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Clozapine (CLZ); an atypical antipsychotic drug, is well known to have a significant role in managing schizophrenic patients with substance use disorder (SUD). Unfortunately, many patients are deprived of CLZ benefits due to its limited prescription. This is based upon concerns regarding the critical side effects of CLZ in case of overdosing especially, with the lack of accessible therapeutic drug monitoring (TDM) tools. In this contribution, a simple, accurate and sensitive electrochemical method is proposed for CLZ assay in human saliva. Unlike previously reported methods for TDM of CLZ that depends on invasive matrices as plasma and urine, this method employs electrochemical approaches in exploring human saliva as a patient-friendly alternative for assessing CLZ. The proposed method employs differential pulse voltammetry (DPV) with a sensitive and selective Ag-doped ZnO nanoparticles based carbon paste electrode (CPE). The adopted electrochemical sensor has not been previously reported for CLZ determination, despite it offers enhanced sensitivity together with simple synthesis. The synthesized nanoparticles were characterized through Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The developed sensor was optimized and validated as per FDA guidelines of bioanalytical methods. The linear range in saliva was 0.31-3.67 µmol/L and the lower limit of quantitation (LLOQ) was 0.31 µmol/L. The high reliability and applicability of the suggested method has strong potential to be integrated in a point-of-care testing (POCT) device to introduce more accessible TDM that enables smooth TDM of CLZ. Therefore, it opens pathways for broader and safe use of CLZ.

Indexed as

Ag-doped ZnO nanoparticlesClozapineElectrochemical sensorPoint-of-care testSalivaTherapeutic drug monitoring

Identifiers

PMID41241755
PMCPMC12619149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.