Evidence map›Paper›PMID 41239048›Full record

ReviewEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2025

Influence of fracture morphology and working length on shear motion and construct stiffness in osteosynthesis constructs.

Marianne Hollensteiner, Mischa Mühling, Philipp Blum, Sabrina Sandriesser, Dirk Baumeister, Markus Greinwald, Julian Fürmetz, Peter Augat

Abstract readReview
In one paragraph

Review in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Marianne HollensteinerInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany. Marianne.hollensteiner@bgu-murnau.de.
Mischa MühlingInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Philipp BlumInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Sabrina SandriesserInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Dirk BaumeisterInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Markus GreinwaldInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Julian FürmetzDepartment of Trauma Surgery, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Peter AugatInstitute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundConstruct stability is a key factor in fracture healing and is influenced by fracture morphology, working length, and fixation strategy. While osteotomized fracture models are widely used for biomechanical testing, their relevance to real, interdigitated fracture patterns remains unclear.

methodsThis study compared the axial stiffness, torsional stiffness, and interfragmentary shear motion of synthetic distal femur models with osteotomized and realistic fractures. All constructs were tested under axial and torsional loading while progressively reducing the number of diaphyseal screws from five to two, thereby increasing the working length. Realistic fractures with a gap were analyzed in both an "open" state (prior to contact) and a "contact" state (after fragment contact. Shear displacements were quantified as resultant vectors derived from 3D motion tracking.

resultsFracture morphology and screw number significantly affected construct stiffness and shear motion. Osteotomized fractures showed higher axial stiffness (up to 997 N/mm in OC) compared to realistic fractures (up to 792 N/mm in RC), while realistic fractures without a gap exhibited superior torsional stability (up to 7.4 Nm/° in RC). Increasing working length reduced axial stiffness by up to -24% and torsional stiffness by up to -51%. Shear displacement increased with reduced screw number, particularly in constructs with a fracture gap.

conclusionRealistic fractures exhibit complex and direction-dependent stabilization mechanisms that are not captured by osteotomized models. Working length strongly influences construct behavior across all configurations. This study highlights the biomechanical differences between osteotomized and realistic fractures. Osteotomized models remain valuable as reproducible worst-case scenarios, whereas realistic fractures provide complementary insights by capturing stabilizing mechanisms such as fragment interlocking. Both approaches should therefore be combined in biomechanical research. Clinically, the results underline the importance of anatomical reduction and fixation planning to maximize construct stability.

Indexed as

Femoral FracturesFracture Fixation, InternalBiomechanical PhenomenaBone ScrewsHumansMaterials TestingModels, AnatomicOsteotomyAxial stiffnessDistal femurFracture morphologyInterfragmentary motionOsteosynthesisShear displacementTorsional stiffnessWorking length

Identifiers

PMID41239048
PMCPMC12618379

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.