Evidence map›Paper›PMID 41239032›Full record

ArticleAnnals of biomedical engineering2026

Modes of Leaflet Fluttering: Quantitative Characterization of a Bovine Bioprosthetic Heart Valve.

Silje Ekroll Jahren, Bernhard Vennemann, Karoline-Marie Bornemann, Thomas Rösgen, Dominik Obrist

Erratum issuedAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Silje Ekroll JahrenARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland. silje.jahren@unibe.ch.ORCID http://orcid.org/0000-0003-3931-5141
Bernhard VennemannARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland.
Karoline-Marie BornemannARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland.
Thomas RösgenInstitute of Fluid Dynamics, ETH Zürich, Zurich, Switzerland.
Dominik ObristARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland.

Funding

Swiss Super Computing Center (CSCS) s1240
6 · The paper itself

Abstract

Oscillations of aortic bioprosthetic heart valve (BHV) leaflets during systole are known as leaflet fluttering (LF). LF may be relevant for assessing valvular function and could play a role in structural valve deterioration. However, a quantitative characterization of LF and its underlying physical processes is still missing. The objectives of this study are to systematically characterize LF for a BHV in vitro and to investigate the associated flow structures using a computational model. Leaflet motion of a bovine BHV was captured with high-speed cameras in an in vitro flow loop under varying experimental conditions (cardiac output (CO), inflow, and valve and aortic root orientation). A fluid-structure interaction (FSI) study was conducted for the same BHV for one condition to examine the blood flow patterns associated with LF. In vitro, LF presents in two different modes: either as high-frequency (150-380 Hz), low-amplitude (0.2-0.8 mm) vibrations of the leaflet tips (V-mode) or low frequency (30-90 Hz), high-amplitude (0.4-2.6 mm) waves travelling from leaflet base to tip (T-mode). We observed that LF depends on individual leaflet properties, is more likely to occur, and increases in amplitude and frequency with higher CO, and is also affected by the inflow. The FSI study confirms the presence of the same two modes. We identified large-scale vortex shedding related to the T-mode, superimposed with small-scale vortex shedding connected to vibrations of the leaflet tip (V-mode). Both identified LF modes are potential factors in BHV degeneration and should be considered in the BHV's design.

Indexed as

Aortic ValveBioprosthesisHeart Valve ProsthesisModels, CardiovascularAnimalsCattleBovine bioprosthetic heart valvesFluid-structure interactionLeaflet flutteringStructural valve deterioration

Identifiers

PMID41239032
PMCPMC12852234

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.