ArticleRadiological physics and technology2026
Automatic measurement of pharyngeal contraction ratio during deglutition using 2D cine MRI with deep learning: A pilot study.
Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to develop a deep learning-based method for automatic segmentation of the pharyngeal area (PA) and measurement of the pharyngeal contraction ratio (PCR) during deglutition using cine magnetic resonance imaging (MRI). The proposed algorithm combines PA region extraction by a 2D U-Net with automatic calculation of PA and PCR. Segmentation performance was evaluated using the Dice coefficient (DC), and the PCR measured by the model ([Formula: see text]) was compared with that obtained manually ([Formula: see text]) using correlation and Bland-Altman analyses. Cine MRI data of 20 healthy adults (10 men, 10 women; age 22-29 years) were analyzed. The average DC in the test cases was 0.890 ± 0.025, and the PA of the model correlated well with the manual reference (r = 0.70-0.97). The mean [Formula: see text] was 0.105 ± 0.035, consistent with values reported in videofluoroscopic swallowing studies. These results demonstrate the technical feasibility of automatic PCR measurement from cine MRI using deep learning.
Indexed as
Identifiers
41236586What OpenQuestion holds