Evidence map›Paper›PMID 41236102›Full record

ArticleMagnetic resonance in medicine2026

Comprehensive 4D Parallel Transmission Spatial-Spectral Pulse Design for Slab-Selective Uniform Water-Selective Excitation: Demonstration in the Human Brain at 7 Tesla.

Xin Shao, Zhe Zhang, Wen Zhong, Hua Guo, Kamil Ugurbil, Xiaoping Wu

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xin ShaoCenter for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.ORCID https://orcid.org/0000-0002-5986-2487
Zhe ZhangTiantan Neuroimaging Center of Excellence, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Wen ZhongCenter for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
Hua GuoCenter for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.ORCID https://orcid.org/0000-0002-0482-1493
Kamil UgurbilCenter for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA.ORCID https://orcid.org/0000-0002-8475-9334
Xiaoping WuCenter for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA.ORCID https://orcid.org/0000-0001-6021-9088

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger, KAMIL UGURBIL · 2019 to 2026
$11.7M
Elementary Neuronal Ensembles to Whole Brain Networks: Ultrahigh Resolution Imaging of Function and Connectivity in Humans - SUPPLEMENTU01EB025144 · NIBIB · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2017 to 2022
$9.7M
Ultrahigh-resolution Functional MRI of the Human Brain at 10.5 TeslaR01NS136490 · NINDS · UNIVERSITY OF MINNESOTA · PI Luca Vizioli, Xiaoping Wu · 2024 to 2026
$1.7M
NIBIB NIH HHS P41 EB027061NIBIB NIH HHS U01 EB025144NIH HHS P41 EB027061NIH HHS R01 NS136490NIH HHS U01 EB025144NINDS NIH HHS R01 NS136490
6 · The paper itself

Abstract

purposeTo propose a new parallel transmission (pTx) spatial-spectral (SPSP) pulse design for achieving slab-selective uniform water-selective excitation without unwanted out-of-slab fat excitation when using bipolar slab-selective gradients to maintain a sharp slab profile.

methodsOur new pTx SPSP pulses were designed by formulating the design problem comprehensively in the 4D space (1D spectral and 3D spatial domains) and by incorporating a SPINS-like 2D excitation k-space trajectory for within-slab flip-angle homogenization. Our new design was validated at 7 T using simulation, phantom and human experiments with the commercial Nova eight-channel transmit RF head coil. Its utility was demonstrated by comparing to traditional multi-spoke pTx SPSP pulses.

resultsIn both simulation and experiments, our design outperformed traditional approaches, producing slab-selective uniform water-selective excitation with no out-of-slab fat excitation. Quantitatively, coefficient of variation measuring excitation non-uniformity reduced by up to ∼23%.

conclusionOur proposed new design provides an effective solution for slab-selective uniform water-selective excitation, holding a promise to many applications including mesoscale BOLD fMRI and fat-free body imaging at ultrahigh field.

Indexed as

BrainImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingAlgorithmsComputer SimulationHumansPhantoms, ImagingReproducibility of ResultsWaterWaterparallel transmissionradiofrequency pulse designslab‐selective excitationspatial‐spectral pulse designwater‐selective excitation

Identifiers

PMID41236102
PMCPMC12673673

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.