ArticleTranslational cancer research2025

A diagnostic test evaluation: dynamic optical functional imaging system for early-stage breast cancer detection.

Xiangming He, Linyin Fan, Jian Huang, Xiping Zhang, Naohiro Ishii, Xiaojia Wang, John Zhang

Abstract read
In one paragraph

Article in Translational cancer research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiangming HeBreast Center, Zhejiang Cancer Hospital, Hangzhou, China.
Linyin FanBreast Center, Zhejiang Cancer Hospital, Hangzhou, China.
Jian HuangBreast Center, Zhejiang Cancer Hospital, Hangzhou, China.
Xiping ZhangBreast Center, Zhejiang Cancer Hospital, Hangzhou, China.
Naohiro IshiiDepartment of Plastic and Reconstructive Surgery, International University of Health and Welfare Narita Hospital, Narita, Chiba, Japan.
Xiaojia WangBreast Center, Zhejiang Cancer Hospital, Hangzhou, China.
John ZhangDOBI Medical, Shirley, MA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The Dynamic Optical Breast Imaging (DOBI) ComfortScan system is a dynamic optical breast functional imaging system that analyses diffused light propagation through breast tissue. It continuously records the physiological properties of the tissue by applying a certain amount of pressure to the breasts that induces changes in blood hemoglobin concentration and the metabolic rates associated with the tumor angiogenesis of breast cancer. This study examined the clinical performance of dynamic optical functional imaging in the detection of malignant lesions, and compared the DOBI system with conventional imaging modalities. This novel diagnostic test addresses critical limitations of conventional imaging by providing functional assessment of tumor angiogenesis through hemoglobin dynamics, particularly valuable for dense-breast patients where mammography (MG) sensitivity declines. Methods: Patients with clinical ultrasound (US) and/or MG results, as well as biopsy results, at the Zhejiang Cancer Hospital in China were recruited for this study between March 2022 and November 2023. The study was designed to evaluate the effectiveness of the DOBI system in diagnosing malignant lesions of the breast. The pathology results from a surgical or core-needle biopsy were used as the standard. We prospectively enrolled 282 patients (320 lesions) with biopsy-confirmed diagnoses from Zhejiang Cancer Hospital [2022-2023]. Diagnostic accuracy metrics (sensitivity, specificity, positive predictive value and negative predictive value) were calculated against histopathology gold standard, with comparative analysis against US, MG, and magnetic resonance imaging (MRI). Results: The data of 320 lesion cases were collected, including both the biopsy results and DOBI images. Of these, 180 cases had DOBI, US, and biopsy results, while 149 cases had DOBI, MG, and biopsy results. The accuracy (ACC), sensitivity (SEN), specificity (SPE), positive predictive value (PPV), and negative predictive value (NPV) of the DOBI system for breast cancer diagnosis were 81.25%, 95.96%, 74.66%, 62.91%, and 97.63%, respectively. The cohort comprised 35% malignant (n=98) and 65% benign (n=184) lesions, predominantly in 40-60 years old (67%) with A/B-cup breasts (87%). DOBI demonstrated 95.96% sensitivity and 74.66% specificity, outperforming US (91.38%/57.6%) and comparable to MG (78.57%/85.32%). Conclusions: The DOBI system had both a high SEN (95.96%) and a high NPV (97.63%), as well as an acceptable SPE (74.66%). This suggests that it has the potential to serve as a supplementary diagnostic method for the detection of breast cancer. The study also showed that combining the DOBI system with conventional imaging modalities (e.g., US or MG) could significantly reduce false-negative (FN) and false-positive (FP) breast cancer diagnoses. As a radiation-free, low-cost functional imaging tool, DOBI shows potential as a triage test to reduce unnecessary biopsies (FP reduction: US 52→15, MG 16→3) and prevent missed diagnoses (FN elimination: US 5→0, MG 9→0) when combined with conventional imaging. Multicenter validation is warranted given single-center design limitations.

Indexed as

Breast cancerdynamic optical breast functional imagingoptical imaging

Identifiers

PMID41234895
PMCPMC12605326

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.