Evidence map›Paper›PMID 41234615›Full record

ReviewDigital health

Wearable vital-sign sensors for early detection of severe dengue and sepsis: Clinical applications and implementation in resource-limited settings.

Mohamed Mustaf Ahmed, Zhinya Kawa Othman, Sumaya Mahamud Mahamed, Olalekan John Okesanya, Shuaibu Saidu Musa, Francesco Branda, Don Eliseo Lucero-Prisno

Abstract readReview
In one paragraph

Review in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mohamed Mustaf AhmedFaculty of Medicine and Health Sciences, SIMAD University, Mogadishu, Somalia.ORCID https://orcid.org/0009-0006-5991-4052
Zhinya Kawa OthmanDepartment of Pharmacy, Kurdistan Technical Institute, Sulaymaniyah, Iraq.ORCID https://orcid.org/0009-0008-3914-0867
Sumaya Mahamud MahamedFaculty of Medicine and Health Sciences, SIMAD University, Mogadishu, Somalia.ORCID https://orcid.org/0009-0008-4838-6594
Olalekan John OkesanyaDepartment of Public Health and Maritime Transport, University of Thessaly, Volos, Greece.ORCID https://orcid.org/0000-0002-3809-4271
Shuaibu Saidu MusaSchool of Global Health, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0003-0138-3261
Francesco BrandaUnit of Medical Statistics and Molecular Epidemiology, Campus Bio-Medico University of Rome, Rome, Italy.ORCID https://orcid.org/0000-0002-9485-3877
Don Eliseo Lucero-PrisnoDepartment of Global Health and Development, London School of Hygiene and Tropical Medicine, London, UK.ORCID https://orcid.org/0000-0002-2179-6365

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Severe dengue and sepsis account for tens of millions of cases and deaths annually in low-resource settings, where spot-check vital sign monitoring misses early physiological deterioration. Affordable wearable sensors that stream continuous data and feed machine learning algorithms promise earlier detection and improved outcomes. Methods: We conducted a structured narrative literature review of human studies on PubMed, Embase, Scopus, and Google Scholar that evaluated wearable vital-sign devices for predicting severe dengue or sepsis in resource-limited areas. Two reviewers independently screened, extracted, and synthesized data on study design, devices, vital streams, predictive performance, and implementation barriers. Results: Seven eligible studies (2019-2024) from Vietnam, Rwanda, Bangladesh, and South Korea tested photoplethysmography or single-lead electrocardiography wearables in intensive care units and emergency departments of hospitals. The algorithms achieved an area under the receiver operating characteristic curve of 0.83-0.86 for forecasting dengue shock up to 2 hours and sepsis deterioration up to 5-48 hours before conventional recognition. The precision reached 0.79 for the three-level dengue severity classification. Continuous monitoring reduces the time to intervention and matches or exceeds the accuracy of manual charting. Conclusion: Early evidence shows that low-cost wearable sensors can deliver clinically meaningful lead times for severe dengue and sepsis in developing countries' hospitals. However, generalizability, artifact suppression, power autonomy, and economic sustainability remain unproven. Multicentre pragmatic trials, edge-optimized algorithms, and full cost-effectiveness analyses are needed before routine adoption.

Indexed as

dengueearly warninglow-resource settingssepsisvital-sign monitoringWearable sensors

Identifiers

PMID41234615
PMCPMC12605882

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.