Effect of different artifact reduction methods for quantitative computed tomography measurements of bone mineral density: a pilot study.

Ranxu Zhang, Yijing Wang, Lin Bai, Zishuo Hou, Yunyu Yan, Shushan Dong, Jian Zhao, Ping Zhang

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ranxu ZhangDepartment of CT/MRI, Hebei Medical University Third Hospital, No.139, Ziqiang Street, Qiaoxi Disstrict, Shijiazhuang, 050051, China.
Yijing WangDepartment of Radiology, Hebei General Hospital, No.348, Heping Street, Xinhua District, Shijiazhuang, 050051, China.
Lin BaiDepartment of CT/MRI, Hebei Medical University Third Hospital, No.139, Ziqiang Street, Qiaoxi Disstrict, Shijiazhuang, 050051, China.
Zishuo HouDepartment of CT/MRI, Hebei Medical University Third Hospital, No.139, Ziqiang Street, Qiaoxi Disstrict, Shijiazhuang, 050051, China.
Yunyu YanDepartment of CT/MRI, Hebei Medical University Third Hospital, No.139, Ziqiang Street, Qiaoxi Disstrict, Shijiazhuang, 050051, China.
Shushan DongClinical Science, Philips healthcare, Shanghai, China.
Jian ZhaoDepartment of CT/MRI, Hebei Medical University Third Hospital, No.139, Ziqiang Street, Qiaoxi Disstrict, Shijiazhuang, 050051, China. 37400408@hebmu.edu.cn.
Ping ZhangDepartment of CT/MRI, Hebei Medical University Third Hospital, No.139, Ziqiang Street, Qiaoxi Disstrict, Shijiazhuang, 050051, China. 38500364@hebmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe increasing use of metal internal fixation devices has heightened clinical concerns about peri-implant complications, such as osteoporosis, fracture risk, and hardware loosening. Quantitative computed tomography (QCT) is employed for the quantitative assessment of bone mineral density (BMD) at specific anatomical sites in clinical settings, while conventional CT is used to visualize the structures surrounding the implant. However, significant metal artifacts present in the images can impede the observation and diagnosis of adjacent bone structures. This study systematically evaluates the combined use of orthopedic metal artifact reduction (O-MAR) algorithms and virtual monoenergetic imaging (VMI) to improve image quality and the accuracy of BMD measurements within QCT protocols.

methodsThree metal screws were inserted into each of five porcine femoral specimens, followed by dual-layer spectral detector CT scanning. Reconstructed images were divided into five groups: conventional imaging (CI), O-MAR, VMI, VMI + O-MAR, and CI images after metal implant removal (CI*). Quantitative analysis was conducted by recording attenuation (HU), calculating the signal-to-noise ratio (SNR) and artifact index (AI) of cancellous bone, and measuring BMD via QCT.

resultsSignificant differences in HU, SNR, and AI were observed among metal artifact reduction methods. The CI group demonstrated the highest attenuation and SNR (P < 0.05 vs. other groups), while VMI and VMI + O-MAR showed reduced HU values and the lowest SNR (P < 0.05). Both VMI groups exhibited superior artifact reduction (lower AI) compared to other groups. QCT indicated that BMD measurements were lower in the VMI groups compared to the CI or CI* groups (P < 0.05), though O-MAR maintained BMD accuracy comparable to CI*.

conclusionO-MAR and VMI effectively reduced metal artifacts, although excessive suppression of artifacts by high-energy VMI may compromise bone quality assessment. The standalone application of O-MAR may facilitate more accurate BMD quantification.

Indexed as

ArtifactsBone DensityFemurTomography, X-Ray ComputedAlgorithmsAnimalsBone ScrewsMetalsPilot ProjectsSwineMetalsBone mineral densityOrthopedic metal artifact reductionQuantitative computed tomographyVirtual monoenergetic images

Identifiers

PMID41233769
PMCPMC12616936

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.