Evidence map›Paper›PMID 41233625›Full record

ArticleSurgical and radiologic anatomy : SRA2025

Feasibility of MRI with zero echo time (ZTE) sequence for personalized preoperative assessment of distances between critical nerves and glenoid landmarks.

Bahattin Paslı, Vedat Yaman, Ceren Günenç Beşer, Gazi Huri, Mehmet Deniz Demiryürek, Üstün Aydıngöz

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical and radiologic anatomy : SRA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bahattin PaslıDepartment of Anatomy, Hacettepe University School of Medicine, 06230, Ankara, Türkiye. bahattin.pasli@hacettepe.edu.tr.ORCID http://orcid.org/0000-0002-4354-3238
Vedat YamanDepartment of Radiology, Hacettepe University School of Medicine, 06230, Ankara, Türkiye.ORCID http://orcid.org/0000-0002-8663-9774
Ceren Günenç BeşerDepartment of Anatomy, Hacettepe University School of Medicine, 06230, Ankara, Türkiye.ORCID http://orcid.org/0000-0002-8230-3974
Gazi HuriDepartment of Orthopedics and Traumatology, Hacettepe University School of Medicine, 06230, Ankara, Türkiye.ORCID http://orcid.org/0000-0002-7036-8455
Mehmet Deniz DemiryürekDepartment of Anatomy, Hacettepe University School of Medicine, 06230, Ankara, Türkiye.ORCID http://orcid.org/0000-0001-8781-1719
Üstün AydıngözDepartment of Radiology, Hacettepe University School of Medicine, 06230, Ankara, Türkiye.ORCID http://orcid.org/0000-0002-4325-847X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess the feasibility of MRI with zero echo time (ZTE) sequence for evaluating proximity of axillary and suprascapular nerves to glenoid landmarks relevant to shoulder surgery.

methodsClosest distances between axillary nerve and inferior glenoid rim (Parameter 1), between suprascapular nerve in suprascapular notch and superior glenoid rim (Parameter 2), and projectional distance between suprascapular nerve in spinoglenoid notch and glenoid articular surface (Parameter 3) were measured on shoulder ZTE MRI. Measurements were made by two observers on multiplanar reformatted ZTE images that showed osseous outline, employing triangulation on standard protocol images for nerves. Parameter 1 measurement was duplicated on a single fresh frozen cadaver.

resultsThis study included 211 consecutive patients (147 females [69.7%] and 64 males [30.3%]), with a mean age of 55.1 ± 15.2 years (range, 18–85). ZTE MRI was validated by corresponding cadaveric measurement, with Parameter 1 measuring 17.1 mm on ZTE MRI and 17.2 mm on the cadaver. Mean values for Parameters 1‒3 were 15.1 ± 3.9 mm (95% CI 14.6–15.6), 29.0 ± 3.3 mm (95% CI 28.5–29.4), and 13.4 ± 2.7 mm (95% CI 13.0–13.7), respectively. Inter-rater agreement was good or excellent (ICCs, 0.876–934) and intra-rater agreement was excellent (ICCs, 0.939–0.972). Males had higher values for Parameters 1 and 2 (p < 0.001), with no difference for Parameter 3 (p = 0.237).

conclusionMRI with ZTE is a feasible technique for preoperative measurements between glenoid landmarks and axillary or suprascapular nerves, potentially reducing the risk of iatrogenic injury during shoulder surgery without exposure to ionizing radiation.

Indexed as

Anatomic LandmarksBrachial PlexusGlenoid CavityMagnetic Resonance ImagingShoulder JointAdolescentAdultAgedAged, 80 and overAxillaCadaverFeasibility StudiesFemaleHumansMaleMiddle AgedArthroscopyMagnetic resonance imagingPreoperative planningReverse total shoulder arthroplastySLAP lesion

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked