Evidence map›Paper›PMID 41233476›Full record

ArticleScientific reports2025

A quasi-oppositional FBI algorithm driven fuzzy cascaded fractional-order controller for enhancing transient stability in hybrid power systems.

Jugajyoti Sahu, Bhabasis Mohapatra, Jyoti Ranjan Nayak, Binod Kumar Sahu, Pradeep Kumar Mohanty, Mohit Bajaj, Olena Rubanenko, Ezzeddine Touti

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jugajyoti SahuDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, India.
Bhabasis MohapatraDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, India.
Jyoti Ranjan NayakDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, India.
Binod Kumar SahuDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, India. binoditer@gmail.com.
Pradeep Kumar MohantyDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, India.
Mohit BajajDepartment of Electrical Engineering, Graphic Era (Deemed to be University), Dehradun, 248002, India.
Olena RubanenkoDepartment of Power Plants and System, Vinnytsia National Technical University, Vinnytsia, 21000, Ukraine. olenarubanenko@vntu.edu.ua.
Ezzeddine ToutiCenter for Scientific Research and Entrepreneurship, Northern Border University, 73213, Arar, Saudi Arabia. esseddine.touti@nbu.edu.sa.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The basic contemplate of this work is to enhance the power and frequency variances of power system. The integration of wind and solar energy along with pumped hydrogen energy storage (PHES) may enhance the challenge to maintain the stability of the system. The design of smart and knowledgeable controller is immensely obligatory for stability of hybrid power system. In this work, intelligent fuzzy fractional order proportional integral derivative cascaded with 1 + fractional order proportional integral (FFOPID (1 + FOPI)) is designed for frequency regulation of power system. The immensely influential parameters of proposed FFOPID (1 + FOPI) controller are decided by forensic-based investigation (FBI) and quasi oppositional-based FBI (QOFBI) algorithms. The integration of QOFBI and FFOPID (1 + FOPI) is tested in four different power system environments over other controllers. The supremacy of proposed QOFBI based FFOPID (1 + FOPI) controller is confirmed through simulation result analysis by considering some statistical errors such as undershoot, overshoot, settling time and integral of time-weighted absolute error. The improvement of proposed controller over other controllers is quietly detectable in terms of frequency and tie-line power deviations. These results demonstrate that intelligent optimization in conjunction with fuzzy logic based fractional-order control can effectively increase system robustness in transient scenarios. The results of this research demonstrate that PHES is an appropriate choice for preserving frequency stability throughout the development of smart and renewable-dominated power grids when combined with RESs.

Indexed as

Fractional-order controller and quasi oppositional FBI (QOFBI)Grid stabilityPumped hydrogen energy storage (PHES)Renewable energy sources (RESs)Transient stability analysis

Identifiers

PMID41233476
PMCPMC12615760

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.