Evidence map›Paper›PMID 41233371›Full record

ArticleScientific reports2025

Impact of anatomical adaptation in cemented femoral stems on mechanical properties and alignment.

Tomohiro Shimizu, Tetsuro Oue, Tatsuhiro Ishijima, Michihiro Fujiwara, Yoshihiro Hasebe, Keita Uetsuki, Norimasa Iwasaki, Daisuke Takahashi

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tomohiro Shimizu *Department of Orthopaedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, 060-8638, Japan. simitom@wg8.so-net.ne.jp.ORCID http://orcid.org/0000-0001-6760-3066
Tetsuro Oue *Department of Orthopaedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, 060-8638, Japan.
Tatsuhiro IshijimaDepartment of Orthopaedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, 060-8638, Japan.
Michihiro FujiwaraR&D Center, Nakashima Healthforce Co., Ltd., Okayama, 701-1221, Japan.
Yoshihiro HasebeR&D Center, Nakashima Healthforce Co., Ltd., Okayama, 701-1221, Japan.
Keita UetsukiR&D Center, Nakashima Healthforce Co., Ltd., Okayama, 701-1221, Japan.
Norimasa IwasakiDepartment of Orthopaedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, 060-8638, Japan.
Daisuke TakahashiDepartment of Orthopaedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, 060-8638, Japan. rainbow-quest@pop02.odn.ne.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Polished tapered femoral stems are widely used in total hip arthroplasty (THA) for their excellent long-term outcomes. However, anatomical mismatches in Asian populations increase the risk of periprosthetic femoral fractures and malalignment. This study evaluated the mechanical properties and radiographic alignment of the VLIAN stem-a cemented, polished, double-tapered stem with a rounded shoulder design developed for Asian femoral anatomy-compared to the Exeter stem. Mechanical testing assessed rotational resistance and stiffness using cobalt-chromium stems cemented into custom jigs and composite femur models. Rotational torque and load-displacement curves were analyzed. For clinical evaluation, 654 Japanese patients undergoing primary cemented THA were retrospectively reviewed: 275 received the Exeter stem (2013-2018) and 379 the VLIAN stem (2018-2023). Radiographs were analyzed for stem alignment, Dorr classification, and femoral neck-shaft angle. Results showed no significant difference in rotational resistance or construct stiffness between designs. Radiographic analysis demonstrated significantly smaller varus angles with the VLIAN stem, particularly in Dorr type C femurs and those with lower neck-shaft angles. These findings suggest that anatomical design modifications, such as a rounded shoulder, improve alignment without compromising mechanical strength. Further studies are needed to evaluate long-term clinical outcomes.

Indexed as

Arthroplasty, Replacement, HipFemurHip ProsthesisProsthesis DesignAgedAged, 80 and overBiomechanical PhenomenaBone CementsFemaleHumansMaleMiddle AgedRetrospective StudiesBone CementsAsian anatomyFemoral stem designImplant anatomyRounded shoulder stemTotal hip arthroplasty

Identifiers

PMID41233371
PMCPMC12615584

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.