ArticleCanadian journal of kidney health and disease2025
Development and Evaluation of a Kidney Point-Of-Care Ultrasound (POCUS) Training Program for Nephrology Fellows: A Quality Improvement Study.
Article in Canadian journal of kidney health and disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Point of care ultrasound (POCUS) has become increasingly integrated into routine clinical care, though its adoption in nephrology remains limited. Objective: This pilot study evaluated a program to train nephrology fellows to perform POCUS to detect small kidney size and hydronephrosis. Design and Setting: We performed a quality improvement initiative at a single academic center (St. Michael's Hospital). Patients: 63 patients were included. Measurements: Pre- and post-workshop surveys assessed trainees' comfort level with kidney POCUS imaging. Patient satisfaction was also measured using a questionnaire. Time to kidney imaging, radiologic diagnosis and kidney POCUS diagnostic accuracy were also assessed. Methods: Nephrology fellows participated in two 1-hour workshops featuring didactic and hands-on training using POCUS machines, after which they scanned hospitalized patients. Results: Sixty-two native kidneys and 32 transplant kidneys were scanned. Patient surveys indicated high satisfaction with POCUS, with 71% preferring bedside ultrasound in future care. Trainee confidence with using POCUS improved post-workshop. Trainee-performed POCUS demonstrated a specificity of 1.00 (95% CI 0.94-1.00) and 0.96 (95% CI 0.80-1.00) for the detection of hydronephrosis in native and transplant kidneys, respectively. Nephrology trainees demonstrated a specificity of 0.75 (95% CI 0.53-0.90) [left native kidneys], 0.81 (95% CI 0.61-0.93) [right native kidneys] and 0.97 (95% CI 0.84-1.00) [transplant kidneys] for the detection of small kidney size. Limitations: The prevalence of hydronephrosis and small kidneys was too low in this pilot study to draw conclusions about sensitivity. Additionally, a majority of the kidneys underwent POCUS imaging after an ultrasound had been performed in the medical imaging department. Conclusions: Despite the increasing demand for POCUS training in nephrology, a significant gap persists in its clinical integration. Our study demonstrates that a structured workshop improves trainee confidence in kidney POCUS, with high patient satisfaction. Preliminary findings suggest that nephrology fellow-performed POCUS is feasible and promising, though further large-scale studies are needed to validate its clinical utility.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.