Bringing the lab home: Evaluating the clinical accuracy of five urinary pH devices for stone prevention.

Marina Garcés Valverde, Pedro Campillo Martinez, Arman Tsaturyan, Angelis Peteinaris, Amelia Pietropaolo, Lukas Nowak, Emre Sener, Liliana E Garcés Proaño, Francisco Javier Lopez Vivo, José Luis Duró-Torrijos and 2 more

Abstract read
In one paragraph

Article in Urology annals. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Marina Garcés ValverdeDepartment of Urology, University Hospital del Vinalopo, Elche, Spain.
Pedro Campillo MartinezDepartment of Urology, University Hospital del Vinalopo, Elche, Spain.
Arman TsaturyanDepartment of Urology, Yerevan State Medical University after Mkhitar, Yerevan, Armenia.
Angelis PeteinarisDepartment of Urology, University Hospital of Patras, Patras, Greece.
Amelia PietropaoloEAU Young Academic Urologists Urolithiasis and Endourology Working Group, Arnhem, The Netherlands.
Lukas NowakEAU Young Academic Urologists Urolithiasis and Endourology Working Group, Arnhem, The Netherlands.
Emre SenerEAU Young Academic Urologists Urolithiasis and Endourology Working Group, Arnhem, The Netherlands.
Liliana E Garcés ProañoDepartment of Urology, University Hospital del Vinalopo, Elche, Spain.
Francisco Javier Lopez VivoDepartment of Urology, University Hospital del Vinalopo, Elche, Spain.
José Luis Duró-TorrijosDepartment of Urology, University Hospital del Vinalopo, Elche, Spain.
Bhaskar K SomaniDepartment of Urology, University Hospital Southampton NHS Foundation Trust, Southampton, UK.
Begoña Ballesta MartinezDepartment of Urology, University Hospital del Vinalopo, Elche, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The aim of this study was to compare the accuracy of five different manual urine pH measurement devices against the laboratory reference method. Materials and Methods: Fresh second-morning midstream urine samples were collected from patients with a history of urolithiasis and from healthy volunteers. Measurements were performed using five different models of manual pH meters purchased from a popular general online shopping platform: Two were paper strip meters (Just Fitter and Simplex Health) and three were electronic meters (Pancellent, Yummici, and GuDoQi [QBY]). Results were compared to the reference method used in the institution's laboratory which uses the Siemens Clinitek Novus machine (Siemens AG, Munich, Germany). The degree of correlation between each device was assessed by calculating the intraclass correlation coefficient (ICC). Results: Seventy-two fresh urine samples were analyzed. The ICC for Just Fitter paper strip meter was 0.792 (95% confidence interval [CI] 0.685-0.865), for Simplex Health paper strip meter was 0.830 (95% CI 0.723-0.895), for Pancellent electronic meter was 0.873 (95% CI 0.804-0.919), for Yummici electronic meter was 0.866 (95% CI 0.780-0.918), and for GuDoQi electronic meter was 0.848 (95% CI 0.555-0.93). Conclusions: All five urinary pH measuring tools showed good correlation with the reference method (ICC > 0.75), with electronic meters being superior to paper strips, and Pancellent brand being the closest to the reference test. According to these results, manual pH meters, especially electronic models may be considered an acceptable alternative to frequent hospital urinary pH measurements.

Indexed as

Kidney stonesoutpatient monitoringpH monitoringurinary pH

Identifiers

PMID41229577
PMCPMC12604687

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.