Scatter Removal in Photon-Counting Dual-Energy Chest X-Ray Imaging Using a Moving Block Method: A Simulation Phantom Study.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparative Evaluation of Machine Learning and Conventional Material Decomposition Algorithms for Spectral Chest Radiography Using a CdTe Photon-Counting Detector.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This work investigates the impact of scatter correction on photon-counting dual-energy chest radiography using a moving block method, focusing on quantifying improvements with the IEC 62220-2-1 dual-energy metrics. A modified LucAl-based chest phantom with PMMA and aluminum inserts was modeled in three sizes (small, standard, large) to represent different patient sizes. Monte Carlo simulations with MC-GPU and the Photon Counting Toolkit were used to simulate a CdTe photon-counting detector with two energy thresholds at 30 and 70 keV. Scatter was estimated from blocker shadows at 25 positions, interpolated across the field of view, and smoothed with a Gaussian filter (σ=5.0 mm), then subtracted separately from low- and high-energy images. Performance was evaluated using the per-feature dual-energy contrast (DEC) and the kerma-normalized dual-energy subtraction efficiency (DSE) with all acquisitions normalized to an entrance air kerma of 1 mGy to reflect clinical exposure conditions. In simulations, the moving block estimate reproduced the true scatter distribution with an average pixel-wise error of 0.4%. Scatter contamination introduced visible artifacts in the dual-energy subtraction images, particularly in aluminum-enhanced (Al-enhanced) images, and reduced contrast for target materials by up to 25%, as reflected in both DEC and DSE values at a fixed dose. Scatter correction restored image contrast, increased DEC for target materials while keeping non-target DEC low, and reduced edge artifacts across phantom sizes with the largest gains in the large phantom. These results support the moving block method as a dose-neutral strategy to improve dual-energy subtraction performance in photon-counting chest radiography.