Evidence map›Paper›PMID 41228914›Full record

ArticleSensors (Basel, Switzerland)2025

Influence of Electrical Transients and A/D Converter Dynamics on Thermal Resistance Measurements of Power MOSFETs.

Krzysztof Górecki, Krzysztof Posobkiewicz

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Krzysztof GóreckiDepartment of Power Electronics, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland.ORCID 0000-0002-9857-8235
Krzysztof PosobkiewiczDepartment of Power Electronics, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland.ORCID 0000-0002-9265-1833

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

When designing power electronic systems, it is crucial to correctly estimate the junction temperature of semiconductor devices, particularly power MOSFETs, under actual operating conditions. Thermal resistance is a parameter that characterizes the ability of these devices to dissipate internally generated heat under steady-state conditions. Determining the value of this parameter under specific cooling conditions requires dedicated measurements. This paper considers the widely used indirect electrical method of measuring thermal resistance. The influence of the dynamic properties of the measurement system, including the A/D converter, on the measurement error of the thermal resistance of power MOSFETs was analyzed. Using the constructed measurement system, it was demonstrated that, depending on the semiconductor material of the tested transistors, different error values were obtained, even with the same system configuration. The largest errors were observed for transistors made of silicon carbide. It was further shown that, with the applied A/D converter module, the measurement error can be limited to a few percent if recording of the thermal sensitive electrical parameter (TSEP) begins soon enough after the transients caused by the switchover from heating to TSEP measurement have fully decayed.

Indexed as

A/D converterselectrical transientsindirect electrical methodmeasurementspower MOSFETsthermal resistancethermal time constants

Identifiers

PMID41228914
PMCPMC12610878