Measurement of Force and Position Using a Cantilever Beam and Multiple Strain Gauges: Sensing Principles and Design Considerations.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Simultaneous measurement of force and position often relies on delicate tactile sensing systems that only measure small forces at discrete positions. This study proposes a compact, durable sensor which can provide simultaneous and continuous measurements of force and position using multiple strain gauges mounted on a cantilever beam. When a point force is applied to the cantilever, the strain gauges are used to determine the magnitude of the applied force and its position along the beam. A major advantage of the force-position sensor concept is its compact electronics and durable sensing surface. We designed, tested, and evaluated three different prototypes for the force-position sensor concept. The prototypes achieved an average percent error of 1.71% and were highly linear. We also conducted a thorough analysis of design variables and their effects on performance. The force and position measurement ranges can be adjusted by tuning the material and geometric properties of the beam and the spacing of the strain gauges. The accuracy of force measurements is dependent upon applied load, but insensitive to the location of the applied load. Accuracy of position measurements is also dependent upon applied load and weakly dependent upon position of the applied load.