Evidence map›Paper›PMID 41228735›Full record

ArticleSensors (Basel, Switzerland)2025

Camera-Based Monocular Depth Estimation in Orthodontics: Vision Transformer vs. CNN Model Performance.

Arda Arısan, Gökhan Serhat Duran

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Arda ArısanIndependent Researcher, Ankara 06000, Turkey.ORCID 0009-0004-8920-8605
Gökhan Serhat DuranDepartment of Orthodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale 17100, Turkey.ORCID 0000-0001-6152-6178

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMonocular Depth Estimation (MDE) is a computer vision approach that predicts spatial depth information from a single two-dimensional image. In orthodontics, where facial soft-tissue evaluation is integral to diagnosis and treatment planning, such methods offer new possibilities for obtaining sagittal profile information from standard frontal photographs. This study aimed to determine whether MDE can extract clinically meaningful information for facial profile assessment.

methodsStandardized frontal photographs and lateral cephalometric radiographs from 82 adult patients (48 Class I, 28 Class II, 6 Class III) were retrospectively analyzed. Three clinically relevant soft-tissue landmarks-Upper Lip Anterior (ULA), Lower Lip Anterior (LLA), and Soft Tissue Pogonion (Pog')-were annotated on frontal photographs, while true vertical line (TVL) analysis from cephalograms served as the reference standard. For each case, anteroposterior (AP) relationships among the three landmarks were represented as ordinal rankings based on predicted depth values, and accuracy was defined as complete agreement between model-derived and reference rankings. Depth maps were generated using one vision transformer model (DPT-Large) and two CNN-based models (DepthAnything-v2 and ZoeDepth). Model performance was evaluated using accuracy, 95% confidence intervals, and effect size measures.

resultsThe transformer-based DPT-Large achieved clinically acceptable accuracy in 92.7% of cases (76/82; 95% CI: 84.8-97.3), significantly outperforming the CNN-based models DepthAnything-v2 (9.8%) and ZoeDepth (4.9%), both of which performed below the theoretical chance level (16.7%).

conclusionsVision transformer-based Monocular Depth Estimation demonstrates the potential for clinically meaningful soft-tissue profiling from frontal photographs, suggesting that depth information derived from two-dimensional images may serve as a supportive tool for facial profile evaluation. These findings provide a foundation for future studies exploring the integration of depth-based analysis into digital orthodontic diagnostics.

Indexed as

Neural Networks, ComputerOrthodonticsPhotographyAdultCephalometryFaceFemaleHumansImage Processing, Computer-AssistedMaleRetrospective StudiesYoung Adultcomputer visionConvolutional Neural Networksmedical imagingMonocular Depth Estimationorthodontic diagnosticsvision transformer

Identifiers

PMID41228735
PMCPMC12610820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.