Evidence map›Paper›PMID 41227936›Full record

ArticleMaterials (Basel, Switzerland)2025

Bond Strength of Adhesive Mortars to Substrates in ETICS-Comparison of Testing Methods.

Paweł Gaciek, Mariusz Gaczek, Paweł Krause

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Paweł GaciekFaculty of Civil Engineering, Silesian University of Technology, 44-100 Gliwice, Poland.
Mariusz GaczekFaculty of Civil and Transport Engineering, Poznan University of Technology, 60-965 Poznan, Poland.ORCID 0000-0003-1349-2676
Paweł KrauseFaculty of Civil Engineering, Silesian University of Technology, 44-100 Gliwice, Poland.ORCID 0000-0002-8398-1961

Funding

Ministry responsible for higher education No. 03/030/SDW22/0158
6 · The paper itself

Abstract

This study investigates the bond strength of fifteen cement-based adhesive mortars used for expanded polystyrene (EPS) in External Thermal Insulation Composite Systems (ETICS). Field surveys and contractor interviews (170 questionnaires) found that adhesive layer thicknesses in real applications typically range from 15-20 mm and frequently exceed 20 mm, in contrast to the smaller values most often recommended by guidelines and technical instructions. Laboratory testing was conducted using two approaches: the standardized pull-off procedure according to EAD 040083-00-0404 (EAD and EAD' variants) and an in-house pull-off procedure designed to reflect practical conditions of substrate type (concrete slab, silicate block), substrate orientation (horizontal, vertical), and adhesive layer thickness (10 and 20 mm). The results showed that adhesive bond strength is strongly influenced by adhesive layer thickness, substrate type, and substrate orientation. Increasing thickness from 10 mm to 20 mm on concrete substrates typically reduced bond strength by about 65-75%, while vertical orientation lowered adhesion to about half of that obtained in horizontal placement. Silicate substrates exhibited generally lower bond strength but higher variability, occasionally with ratios above unity due to their greater porosity. In some configurations, detachment occurred already during specimen preparation, underlining the variability of performance. The combined effect of increased thickness and vertical orientation on concrete substrates reduced adhesion by about 85% compared to the 10 mm horizontal baseline, highlighting the severity of unfavorable application conditions, whereas on silicate blocks, the effect was weaker but accompanied by large variability. The findings indicate that adhesive layer thickness has a stronger impact on bond strength than orientation and that substrate properties play an important role. The study provides a comparative perspective on current and alternative testing approaches, revealing significant differences in the results. The author's testing method makes it possible to account for, in laboratory conditions, primarily the geometric shape and orientation of samples that are close to the actual form of adhesive mortar application in real insulation installations. This allows for the assessment of the properties of mortars and substrates that were not exposed under the conditions of current testing methods. The above provides a basis for further discussion on the inclusion of realistic application conditions in the evaluation of adhesive mortars used for bonding thermal insulation in ETICS, and for the validation assessment of an additional testing method, which is currently of an experimental nature.

Indexed as

adhesive layer thicknessadhesive mortarsbond strengthCAST methodETICSpull-off test

Identifiers

PMID41227936
PMCPMC12610452

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.