Evidence map›Paper›PMID 41222587›Full record

ArticleClinical neuroradiology2026

Radiological Prevalence of Superior Semicircular Canal Dehiscence with Ultra-High-Resolution Photon-Counting Detector CT.

Hiroshi Sakaida, Yasutaka Ichikawa, Akio Yamazaki, Hajime Sakuma

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Photon-counting detector computed tomography for temporal bone: does higher resolution matter?Current opinion in otolaryngology & head and neck surgery · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hiroshi SakaidaDepartment of Otorhinolaryngology-Head and Neck Surgery, Mie University, Tsu, Japan. hsakaida@med.mie-u.ac.jp.
Yasutaka IchikawaDepartment of Radiology, Mie University, Tsu, Japan.
Akio YamazakiDepartment of Radiology, Mie University Hospital, Tsu, Japan.
Hajime SakumaDepartment of Radiology, Mie University, Tsu, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo determine the radiological prevalence of superior semicircular canal (SSC) dehiscence in a Japanese cohort using ultra-high-resolution (0.2 mm slice thickness) photon-counting detector CT (PCD-CT) and compare it with historical data from cadaveric and conventional CT studies.

methodsThis study involved a retrospective analysis of 402 temporal bones from consecutive 201 patients (age range 0-87 years; mean 41.0 ± 26.5 years) who underwent temporal bone PCD-CT for various otologic indications, none of whom had a pre-existing diagnosis of superior semicircular canal dehiscence syndrome (SSCDS). SSC bone thickness was measured, and the presence of dehiscence or thinning was assessed using multiplanar reconstructions, primarily in the Pöschl plane. For cases with identified dehiscence or thinning, a retrospective review of clinical and audiological data was performed.

resultsThe mean thickness of the bone overlying the SSC was 0.87 ± 0.50 mm (range 0-3.52 mm). A definite dehiscence was identified in only 1 of the 402 temporal bones, yielding a radiological prevalence of 0.25% (95% CI: 0.00%-1.54%). Significant thinning of the SSC roof, where the bone was present but too thin to be resolved by the measurement caliper, was noted in an additional 12 temporal bones (2.99%, 95% CI: 1.66%-5.20%). Clinical review revealed that the single case of dehiscence was asymptomatic, and in the thinning cases, otologic symptoms were attributable to co-existing pathologies.

conclusionsThe radiological prevalence of SSC dehiscence identified with 0.2 mm PCD-CT is substantially lower than that reported by most conventional CT studies and closely approximates the true anatomical prevalence of 0.4-0.6% established in cadaveric studies. This finding suggests that the ultra-high spatial resolution of PCD-CT significantly reduces or eliminates false-positive findings attributable to partial volume effects, representing a new benchmark for the accurate radiological assessment of SSCDS.

Indexed as

Semicircular Canal DehiscenceSemicircular CanalsTomography, X-Ray ComputedAdolescentAdultAgedAged, 80 and overChildChild, PreschoolFemaleHumansInfantInfant, NewbornJapanMaleMiddle AgedPartial volume effectPhoton-counting detector CTRadiological prevalenceSuperior semicircular canal dehiscenceTemporal boneThird mobile window

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390