Evidence map›Paper›PMID 41221458›Full record

ArticleMedicine and pharmacy reports2025

The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis.

Brigitta Bokor, Adriana Objelean, Simion Bran, Radu Septimiu Campian, Cristian Vilău

Abstract read
In one paragraph

Article in Medicine and pharmacy reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Brigitta BokorDoctoral School, Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
Adriana ObjeleanDepartment of Prosthetics and Dental Materials, Faculty of Dentistry, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
Simion BranDepartment of Maxillofacial Surgery and Implantology, Faculty of Dentistry, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
Radu Septimiu CampianDepartment of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
Cristian VilăuDepartment of Material Resistance, Faculty of Mechanical Engineering, Technical University of Cluj-Napoca, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim of the study: This study aims to evaluate and compare the stress distribution patterns of two experimental tissue-level, convergent collar implants (one made of Ti-6Al-4V (control) and the other of Roxolid-based (Ti-15Zr) material) using 3D finite element analysis (FEA) under various simulated masticatory conditions. Methods: A 3D finite element model replicating a tissue-level implant with convergent neck design was developed in ANSYS software, incorporating both cortical and trabecular bone geometry. Implants made of Ti-6Al-4V-Grade 5 and Roxolide-type-Ti-15Zr alloy were simulated under axial (0°) and oblique (45° angle) loading forces (50 N, 200 N, 300 N, and 400 N). The von Mises equivalent stress distribution was calculated to assess the biomechanical performance. Results: Under masticatory forces simulation, titanium-alloy implants exhibited maximum stress values (400 N) of 260.38 MPa under axial load and 536.2 MPa under oblique load. Ti-15Zr implants exhibited a slightly lower peak stress of 506.95 MPa under a load of 400 N at a 45° inclination and 240.81 N under axial load. Based on 3D finite analysis, the stress distribution maps showed higher concentration in the implant-abutment connection and the cervical region, particularly under oblique loading. Conclusions: Although titanium implants exhibited higher stress limits, Ti-15Zr implants showed biomechanical stability under oblique simulated forces. Ti-15Zr implants exhibited a more uniform stress distribution with a reduced peak concentration.

Indexed as

convergent collarfinite element analysisparafunctional forcesRoxolidsupracrestal implantTi-15Zr implantstissue-level implanttitanium implants

Identifiers

PMID41221458
PMCPMC12600071

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.