ArticleAnnals of joint2025
Two case reports of greater trochanter fracture at the site of femoral array placement after robotic-assisted hip replacement in the posterolateral approach.
Article in Annals of joint, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Total hip arthroplasty (THA) using robotic assistance aims to improve implant positioning and overall outcomes. However, emerging evidence reveals specific complications such as fractures related to temporary pin or screw placements in these procedures. Case Description: We describe two patients (a 74-year-old woman and a 74-year-old man) who underwent robotic-assisted THA (RA-THA) via a posterolateral approach following the MAKO hip protocol [Mako robotic-arm system (Stryker)]. Both had a relatively proximal femoral array screw placement, selected to avoid possible screw-stem interference as per the manufacturer's guidelines. Postoperative radiographs showed no immediate complications, but each patient returned within 2 weeks complaining of hip pain and difficulty ambulating in the absence of significant trauma. Imaging revealed trochanteric fractures originating through the prior pin or screw tract. One patient was treated conservatively; the other required two surgical interventions, complicated by periprosthetic joint infection. At their most recent follow-ups, both patients reported limping gait related to gluteus medius insufficiency but no persistent pain. Conclusions: These cases highlight greater trochanter fractures as a complication related to femoral array screw placement in RA-THA. Our experiences suggest that current guidelines on "safe zones" for array fixation may require refinement to account for patient-specific bone structure. Additional biomechanical research is needed to identify optimal pin placement and minimize postoperative fractures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.