Evidence map›Paper›PMID 41220944›Full record

ArticleFrontiers in oncology2025

Supersonic gas curtain based ionization beam profile monitor for FLASH proton beam therapy.

Milaan Patel, Narender Kumar, Farhana Thesni, William Butcher, Tony Price, Ruth McLauchlan, Carsten P Welsch

Abstract read
In one paragraph

Article in Frontiers in oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Milaan PatelThe Cockcroft Institute, Sci-Tech Daresbury, Warrington, United Kingdom.
Narender KumarThe Cockcroft Institute, Sci-Tech Daresbury, Warrington, United Kingdom.
Farhana ThesniThe Cockcroft Institute, Sci-Tech Daresbury, Warrington, United Kingdom.
William ButcherThe Cockcroft Institute, Sci-Tech Daresbury, Warrington, United Kingdom.
Tony PriceSchool of Physics and Astronomy, University of Birmingham, Birmingham, United Kingdom.
Ruth McLauchlanDepartment of Radiation Physics & Radiobiology, Imperial College Healthcare NHS Trust, London, United Kingdom.
Carsten P WelschThe Cockcroft Institute, Sci-Tech Daresbury, Warrington, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: FLASH Proton Beam Therapy (FLASH-PBT) combines the precision targeting ability of proton beam with radiobiological advantage of FLASH effect at ultra-high dose rates ( Methods: The SGC-IPM uses a supersonic gas jet shaped into a curtain to measure the 2D transverse profile of the beam. Initial tests of the device was conducted on a DC Pelletron accelerator at Dalton Cumbrian Facility (DCF), Whitehaven, UK, followed by later tests on MC40 cyclotron at the University of Birmingham (UoB), UK. Across both the experiments, the device was directly coupled to the vacuum side of the beamlines and beam profiles were recorded for protons at energies ranging from 4-28 MeV and currents ranging from 1-100 nA, with various beam sizes and shapes. Results: The SGC-IPM successfully measured beam profiles and demonstrated a linear response to beam currents across the measurement range, and its response at different energies was quantified by introducing an energy-dependent detection factor, Discussions: A mathematical model is introduced to show that device's response depends on particle fluence, a quantity independent of dose rate. It's linear response to beam current is used to extrapolate measurements at conventional dose rates to assess its performance at FLASH dose rates. The performance is evaluated in terms of threshold dose required to measure beam profile for a standard 1-liter clinical volume positioned 15-20 cm deep in water. Conclusion: This study presents a viable solution for non-invasive proton beam profile monitoring for FLASH-PBT. The device shows a linear response to beam current within the measurement range. The mathematical model quantifies the device's sensitivity and provides a means to calibrate it for dose estimation.

Indexed as

beam profile monitordiagnosticsFLASH therapyionization profile monitornon-invasiveproton beam therapysupersonic gas jet