ArticleJMA journal2025
Interference of Intravenous Acetaminophen with Continuous Glucose Monitoring System.
Article in JMA journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Challenges of Wearable Biosensors and Ways to Overcome Them.Biosensors · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Sensor-augmented pumps (SAPs) and automated insulin delivery (AID) systems are innovative technologies for diabetes management. Accurate continuous glucose monitoring (CGM) is crucial for their safe and effective use; however, certain commonly used drugs can interfere with CGM accuracy. Although acetaminophen is known to cause falsely elevated CGM glucose values, previous CGM studies have primarily focused on its oral administration, with limited data on intravenous use. We report a case of a CGM reaction after the intravenous administration of acetaminophen in a boy with type 1 diabetes using SAP. The patient received repeated doses of intravenous acetaminophen (15 mg/kg for 15 min) for pain relief. After administration, we recorded a rapid increase in his CGM readings without a corresponding increase in blood glucose levels. The CGM glucose peaked at 29.2 ± 1.9 min (mean ± standard deviation) after administration and an estimated discrepancy of 55 to 114 mg/dL compared with capillary blood glucose measurements. Discrepancies between measured blood glucose and CGM readings were significantly greater at lower glucose levels. These falsely elevated CGM readings could potentially trigger an inappropriate autocorrection bolus in AID systems and increase the risk of hypoglycemia. Medical professionals should be fully aware of acetaminophen-induced CGM interference, particularly the potential risks in patients using AID systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.