Evidence map›Paper›PMID 41214622›Full record

ArticleBMC oral health2025

Characterization and biocompatibility evaluation of a Ti@HA-GO@IL-4 bioactive composite coating for guided bone regeneration in dental implant applications.

Congcong Li, Li Zhao, Xiaotao Chen, Aikepaer Aierken, Min Yu, Chuifan Kong, Wufanbieke Baheti

Abstract read
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Congcong LiDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China.
Li ZhaoDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China.
Xiaotao ChenDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China.
Aikepaer AierkenDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China.
Min YuDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China.
Chuifan KongDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China.
Wufanbieke BahetiDepartment of Stomatology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, China. 54591736@qq.com.

Funding

The Natural Science Foundation of Xinjiang Uygur Autonomous Region 2023D01C78Tianshan Talent" High-level Medical and Health Personnel Training Program TSYC202301B017
6 · The paper itself

Abstract

backgroundPure titanium and titanium alloy implants have been widely utilized in dental implantology due to their excellent biocompatibility and favorable elastic modulus. However, the inherent bioinertness of titanium-based implant surfaces often results in suboptimal osseointegration with surrounding bone tissue. Consequently, surface modification is essential to enhance the osseointegrative capacity of titanium implants.

methodsWe fabricated hydroxyapatite-graphene oxide (HA-GO) coatings via electrochemical deposition and systematically compared four distinct protein loading methods. Ultimately, we developed a hydroxyapatite-graphene oxide/interleukin-4 (Ti@HA-GO@IL-4) coating on pure titanium substrates to investigate its physicochemical properties and biocompatibility.

resultsThe composite coating was successfully fabricated on pure titanium substrates, inducing significant surface modifications including the incorporation of bioactive functional groups, enhanced hydrophilicity, and altered surface morphology. Comparative characterization revealed that the composite coating exhibited superior hydrophilic properties, improved mechanical compatibility with bone tissue, stable Interleukin-4 (IL-4) adsorption and sustained-release behavior, as well as excellent biosafety confirmed by proliferation and adhesion assays using mouse embryo osteoblast precursor (MC3T3-E1) cells, when compared to unmodified titanium controls.

conclusionsTi@HA-GO@IL-4 represents a composite coating material with exceptional physicochemical properties and biological performance. This material demonstrates efficient IL-4 loading capacity and sustained release characteristics, thereby effectively promoting osteogenesis. These findings provide valuable insights for developing bioactive functional materials to enhance implant osseointegration.

Indexed as

Bone RegenerationCoated Materials, BiocompatibleDental ImplantsDurapatiteGraphiteInterleukin-4TitaniumAnimalsCell AdhesionCell ProliferationMaterials TestingMiceOsseointegrationOsteoblastsSurface PropertiesCoated Materials, BiocompatibleDental ImplantsDurapatitegraphene oxideGraphiteInterleukin-4TitaniumEngineered materialsGraphene oxide (GO)Hydroxyapatite (HA)IL-4Implant composite coating

Identifiers

PMID41214622
PMCPMC12599081

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.