Evidence map›Paper›PMID 41213996›Full record

ArticleNature communications2025

Thermoelectric device for active thermal concealment, deception and messaging.

Yue Hou, Xiaosa Liang, Zhaoyu Li, Qianfeng Ding, Zheng Zhu, Xiaolong Sun, Chang Li, Wenjie Zhou, Wei Cao, Yuan Yu and 1 more

Abstract read
In one paragraph

Article in Nature communications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yue Hou *The Institute of Technological Sciences, Wuhan University, Wuhan, China.ORCID http://orcid.org/0009-0005-4383-4384
Xiaosa Liang *The Institute of Technological Sciences, Wuhan University, Wuhan, China.
Zhaoyu Li *School of Power and Mechanical Engineering, Wuhan University, Wuhan, China.
Qianfeng DingThe Institute of Technological Sciences, Wuhan University, Wuhan, China.
Zheng ZhuThe Institute of Technological Sciences, Wuhan University, Wuhan, China.
Xiaolong SunThe Institute of Technological Sciences, Wuhan University, Wuhan, China.
Chang LiThe Institute of Technological Sciences, Wuhan University, Wuhan, China.
Wenjie ZhouThe Institute of Technological Sciences, Wuhan University, Wuhan, China.
Wei CaoThe Institute of Technological Sciences, Wuhan University, Wuhan, China.
Yuan YuInstitute of Physics (IA), RWTH Aachen University, Aachen, Germany. yu@physik.rwth-aachen.de.ORCID http://orcid.org/0000-0002-3148-6600
Ziyu WangThe Institute of Technological Sciences, Wuhan University, Wuhan, China. zywang@whu.edu.cn.ORCID http://orcid.org/0000-0001-9718-1263

Funding

National Natural Science Foundation of China (National Science Foundation of China) 12122408National Natural Science Foundation of China (National Science Foundation of China) 12302220National Natural Science Foundation of China (National Science Foundation of China) 2023YFB4603800
6 · The paper itself

Abstract

Thermal concealment is vital for minimizing the visibility of individuals and vehicles to contemporary infrared surveillance technologies. Traditional approaches, such as emissivity modulation, are effective only in scenarios where the ambient temperature is lower than that of the target and typically exhibit response times on the order of minutes. Other temperature regulation methods generally operate within a restricted temperature range. This work presents an active thermal concealment cloak based on thermoelectric devices, integrating functionalities of infrared camouflage, deception, and information display. By optimizing the circuit design and incorporating a low-reflectivity black porous Ethylene-Vinyl Acetate film, the cloak achieves a uniform temperature distribution, eliminating distinct cold or hot boundaries, and exhibits strong resistance to light interference. Enhanced by bottom-side heat dissipation, the device functions effectively across a wide temperature range from 5.77 °C to 109.16 °C and responds rapidly in just 2.03 seconds. Through the self-developed application, each panel pixel on the device can be independently temperature-controlled, allowing for pre-programmed alterations in the shape and color of the concealed target to enable infrared deception. Additionally, a kirigami structure is employed to enhance the device's bendability, facilitating the implementation of curved camouflage and wearable IR information transmission.

Identifiers

PMID41213996
PMCPMC12603023

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.