Evidence map›Paper›PMID 41213506›Full record

ArticleJournal of the American Association for Laboratory Animal Science : JAALAS2025

Extended Sanitization Frequency for Bottles: Using Volume as an Alternative to Time-Scheduled Replacements for Mice in Disposable Individually Ventilated Caging Systems.

Alyssa L Valentyn, Jackie Olley-Williams, Venus Estrada, Naina M F Silva, Misty Williams-Fritze, Ying Wu, Courtney Easley-Neal, Laurette Burgess

Abstract read
In one paragraph

Article in Journal of the American Association for Laboratory Animal Science : JAALAS, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alyssa L Valentyn1Neurology Discovery - Translational Models Department, Eisai, Inc., Cambridge, Massachusetts; and.
Jackie Olley-Williams2Integrated Data Science, Eisai, Inc., Cambridge, Massachusetts.
Venus Estrada1Neurology Discovery - Translational Models Department, Eisai, Inc., Cambridge, Massachusetts; and.
Naina M F Silva1Neurology Discovery - Translational Models Department, Eisai, Inc., Cambridge, Massachusetts; and.
Misty Williams-Fritze1Neurology Discovery - Translational Models Department, Eisai, Inc., Cambridge, Massachusetts; and.
Ying Wu2Integrated Data Science, Eisai, Inc., Cambridge, Massachusetts.
Courtney Easley-Neal1Neurology Discovery - Translational Models Department, Eisai, Inc., Cambridge, Massachusetts; and.
Laurette Burgess1Neurology Discovery - Translational Models Department, Eisai, Inc., Cambridge, Massachusetts; and.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Guide for the Care and Use of Laboratory Animals specifies that sipper tubes require weekly sanitization, although reduced frequency for sterile, disposable caging components may be justified with performance-based assessments; therefore, extending bottle duration beyond 1 week, and replacing instead at a lower volume limit, may be acceptable if it does not compromise mouse health or water quality. Weekly bottle change for sterile, disposable bottles results in excessive waste of both water and plastic-bottles are typically more than half full at 7 days. A volume-based replacement schedule is a visual alternative to weekly changes for systems using sterile, disposable bottles, reducing the number of bottles processed and facilitating operations by allowing spot changes without the need to date or track bottles. Furthermore, the gravity-drip design of Innovive's Aquavive bottle minimizes contamination, suggesting that water quality and cleanliness may be maintained for longer durations. To assess the impact of a volume-based replacement schedule on mouse health and water quality, C57BL/6NCrl mice at varying housing densities were monitored for changes in animal weight and mean water consumption. At bottle replacement, packed cell volume was collected from individual mice as a marker of hydration status, and water quality was assessed by visual inspection, culture for Escherichia coli and coliform bacteria, and total microbial count. Baseline measurements were collected over 7 days, followed by a volume-based replacement period, where bottles remained on the cage until they reached 100 mL (13-47 days). No significant differences were observed in animal body weight, body condition, water consumption, or packed cell volume, regardless of cage density or the amount of time the bottle was deployed. Microbial analysis showed no bacterial growth in any bottle, and visual inspection showed no turbidity or cloudiness. Based on this information, our institution allowed prefilled disposable, acidified water bottles to be maintained well beyond 7 days, using a volume-based replacement at 100 mL.

Indexed as

HDF, high-density femaleLDF, low-density femalePCV, packed cell volume of bloodSHM, singly housed male

Identifiers

PMID41213506
PMCPMC12694255

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.