Evidence map›Paper›PMID 41211353›Full record

ArticleNature and science of sleep2025

Validation of a Wireless, Self-Applied Device for Sleep Recording in the Paediatric Population.

Antonella Iadarola, Ramona Cordani, Marco Veneruso, Sara Uccella, Lino Nobili

Abstract read
In one paragraph

Article in Nature and science of sleep, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Antonella IadarolaDepartment of Neurosciences, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genoa, Genoa, Italy.ORCID 0009-0008-0425-8435
Ramona CordaniDepartment of Neurosciences, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genoa, Genoa, Italy.
Marco VenerusoDepartment of Neurosciences, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genoa, Genoa, Italy.ORCID 0000-0002-4293-0260
Sara UccellaDepartment of Neurosciences, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genoa, Genoa, Italy.ORCID 0000-0003-4164-2125
Lino NobiliDepartment of Neurosciences, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genoa, Genoa, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Although polysomnography (PSG) is the gold standard for sleep evaluation, its use in children and adolescents is limited by poor compliance and the time-consuming setup required. For the first time in a paediatric population, this study tested the Sleep Profiler (SP), a self-applied ambulatory PSG device previously validated in adults. Patients and Methods: Simultaneous standard PSG and SP recordings were acquired from hospitalized patients (n=14), aged 11 to 15 years, and independently scored by two certified sleep medicine experts, blinded to patient identity. Epoch-by-epoch agreement between manually scored PSG, manually scored SP and automatically scored SP records was assessed using confusion matrices and Cohen's kappa coefficient (κ), with PSG as the reference. Sleep macrostructure measures were compared using Bland-Altman analysis. Results: Manual scoring of SP data (SP1) showed substantial agreement with standard PSG across all stages, particularly for REM (κ=0.83), wake (κ=0.83), and N3 (κ=0.82). By contrast, automatic scoring algorithms (AA1 and AA2) provided by the device performed markedly worse (κ always below 0.70). SP1 resulted particularly strong in stage discrimination (specificity over 96% for wake, N1, N3, REM, and 88% in N2), with a sensitivity above 84% in all stages, except N1, which was lower at 55%. Moreover, Bland-Altman plots showed minimal bias and good agreement for sleep macrostructure parameters. These findings were further supported by a robust interrater reliability between scorers (κ=0.82). Conclusion: The SP represents a reliable tool for sleep monitoring even in contexts where low compliance and time-consuming setups may compromise the quality or feasibility of standard recordings, such as in paediatric populations. While automatic scoring requires further refinement, and relatively small sample size should be considered when interpreting the generalizability of the findings, its robust detection especially of REM and N3 sleep make it suitable for both clinical and research applications.

Indexed as

automatic scoringlow-channel EEGpaediatric patientspolysomnographywearable device

Identifiers

PMID41211353
PMCPMC12593808

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.