Evidence map›Paper›PMID 41210880›Full record

ArticleFrontiers in medicine2025

Automatic measurement of mesenteric vascular and portal vein parameters via PE-NET in the diagnosis of Crohn's disease.

Weize Xu, Liangfang Zheng, Kun Zhang, Bosheng He

Abstract read
In one paragraph

Article in Frontiers in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Weize XuDepartment of Radiology, Affiliated Hospital 2 of Nantong University, Nantong, Jiangsu, China.
Liangfang ZhengDepartment of Radiology, Affiliated Hospital 2 of Nantong University, Nantong, Jiangsu, China.
Kun ZhangSchool of Electrical Engineering and Automation, Nantong University, Nantong, Jiangsu, China.
Bosheng HeDepartment of Radiology, Affiliated Hospital 2 of Nantong University, Nantong, Jiangsu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Vascular changes are concomitant of the course of Crohn's disease (CD). In this study, we evaluated the value of the parallel encoder network (PE-NET) method for the automated measurement of mesenteric vascular and portal vein parameters and explored the performance of PE-NET combined with support vector machine (SVM) classifier in CD diagnosis. Methods: The automatic vascular segmentation model was trained using computed tomography enterography (CTE) imaging data from our hospital based on PE-NET. The segmentation performance of the trained model was evaluated using the sensitivity (SEN), the Dice Similarity Coefficient (DSC), and the Average Hausdorff Distance (AHD). Then, the model was used for the automatic measurement of vascular parameters in the classification set, and machine learning classifier SVM was applied based on selected vessel features. The diagnosis performance of the PE-NET + SVM model was evaluated and compared with that of human radiologists and the clinical biomarkers [C-reactive protein (CRP) and fecal calprotectin (FCP)]. The impact of PE-NET + SVM on the reading time of radiologists was also evaluated. Results: The segmentation dataset included the CTE data from 54 CD patients and 20 healthy controls. The classification dataset included the CTE data from 40 CD patients and 45 healthy controls. We found that PE-NET performed well in the vascular segmentation of the superior mesenteric artery (SMA), portal vein (PV), and abdominal aorta (AA) in both validation sets and the testing set. Vascular parameters were automatically extracted by PE-NET. We found that the mesenteric artery, portal vein, abdominal aorta, and the ratio of portal vein to superior mesenteric artery or abdominal aorta were increased in the testing set, with no statistical difference between the automatic measurement obtained using PE-NET and the manual evaluation of CTE. Moreover, an support vector machine (SVM) classifier was applied for CD diagnosis based on the vascular parameters. The F1 scores indicated the comparable diagnostic ability of PE-NET + SVM to senior radiologists with over 10 years of experience, and the receiver operating curves (ROCs) revealed that the area under the curve (AUC) of PE-NET + SVM was 0.934, which was higher than those of clinical biomarkers such as FCP (AUC of 0.913) and CRP (AUC of 0.893), suggesting the great potential of PE-NET in aiding CD diagnosis. Additionally, the reading time of a junior radiologist on CTE images was significantly reduced and comparable to that of a senior radiologist with the help of PE-NET. Conclusion: The PE-NET enables the automated measurement of mesenteric vascular and portal vein parameters and potentially assists the efficient diagnosis of CD.

Indexed as

computed tomography enterographyCrohn’s diseasedeep learningmesenteric vascularPE-NETportal vein

Identifiers

PMID41210880
PMCPMC12589085

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.