Evidence map›Paper›PMID 41210796›Full record

ArticleACS omega2025

Structural Design and Mechanical Properties of Metal Vascular Stents Fabricated via Laser Powder Bed Fusion.

Jingtao Miao, Suxia Huang, Zhiang Chen, Qilong Wang, Hezong Li

Erratum issuedAbstract read
In one paragraph

Article in ACS omega, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Jingtao MiaoInstitute of New Materials and Technologies, Ural Federal University, 28 Mira St, Yekaterinburg 620002, Russia.ORCID https://orcid.org/0009-0002-7403-6818
Suxia HuangSchool of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan 056038, China.
Zhiang ChenSchool of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan 056038, China.
Qilong WangSchool of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan 056038, China.
Hezong LiSchool of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan 056038, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Against the backdrop of high cardiovascular disease prevalence, personalized vascular stents tailored to complex vascular structures have emerged as a critical research focus in interventional therapy. While laser powder bed fusion (L-PBF) offers a novel approach to customized stent manufacturing, systematic evaluations of its forming accuracy and mechanical performance remain insufficient. This study designed a novel vascular stent featuring double-period unequal-height support rings interconnected by M-shaped struts and monolithically fabricated it from 316L stainless steel using L-PBF. Surface quality was enhanced via electropolishing. Balloon expansion, radial compression, and microtensile testing quantitatively characterized stent expansion performance (radial recoil rate, axial shortening rate), radial strength, and intrinsic material mechanical properties. Results demonstrated that L-PBF achieved unsupported fabrication of fine features (150 μm wall thickness); electropolishing significantly improved surface quality, reducing dimensional deviation from 46.7% to 3.3%. The stent exhibited a radial strength of 840 mN/mm and a remarkably low radial recoil rate of 1.37%. Material yield strength (232 MPa) reached 74.1% of that of wrought 316L alloy, with a fracture elongation of 16.44%, ensuring structural integrity during expansion. However, the axial shortening rate (5.56%) exceeded expectations, primarily due to geometric deviation in high-curvature connecting struts suppressing their compensatory mechanism. The M-type stent demonstrated superior radial support via its asymmetric-height support ring design, confirming L-PBF's feasibility for producing personalized metal vascular stents. Future work necessitates optimization of connecting strut curvature to control axial shortening and integrated topological design with targeted process optimization to advance clinical translation.

Identifiers

PMID41210796
PMCPMC12593961

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.