Evidence map›Paper›PMID 41210050›Full record

ArticleCureus2025

Accurate Repositioning of Deep Brain Stimulation Electrodes May Preserve Clinical Efficacy.

Robert Ziechmann, Katelyn Mann, Kevin Hines, Caio Matias, Ashwini Sharan, Chengyuan Wu

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Robert ZiechmannNeurosurgery, Thomas Jefferson University Hospital, Philadelphia, USA.
Katelyn MannNeurosurgery, Thomas Jefferson University Hospital, Philadelphia, USA.
Kevin HinesNeurosurgery, Thomas Jefferson University Hospital, Philadelphia, USA.
Caio MatiasNeurosurgery, Thomas Jefferson University Hospital, Philadelphia, USA.
Ashwini SharanNeurosurgery, Thomas Jefferson University Hospital, Philadelphia, USA.
Chengyuan WuNeurosurgery, Thomas Jefferson University Hospital, Philadelphia, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objectives Accurate placement of deep brain stimulation (DBS) electrodes is critical for therapeutic efficacy. Repositioning during the initial surgery is common and can achieve sub-millimeter accuracy. The impact of repositioning on clinical outcomes is not well studied, especially in an imaging-guided, imaging-verified ("asleep") workflow. This study evaluates the effect of repositioning on clinical outcomes for people with Parkinson's disease (PD), comparing clinical outcomes in cases where electrodes required repositioning to those where repositioning was not required. Methods We performed a retrospective analysis for PD patients undergoing DBS implantation between July 2018 and November 2024 at a single institution using an "asleep" technique. Electrodes were repositioned if radial error exceeded 1.5 mm or if adverse effects were anticipated based on anatomical electrode location. Radial error and final radial error were measured using the intraoperative O-arm. Clinical outcomes were assessed by percentage improvement in the Movement Disorders Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) part III score. Results Of 172 PD cases, 20 had complete preoperative and postoperative MDS-UPDRS III data, six of which required electrode repositioning. The revision group had a final radial error of 0.86 ± 0.29 mm, similar to 0.91 ± 0.43 mm in the non-revision group (p = 0.44). MDS-UPDRS III improvement was 38 ± 17% in the revision group and 40 ± 26% in the non-revision group (p = 0.44). Patient demographics (age, time since diagnosis, levodopa response) were similar between groups, except for a lower preoperative MDS-UPDRS part III score in the non-revision group (p = 0.04). The study was underpowered to formally detect non-inferiority. Conclusion This data suggests that repositioning sub-optimally placed DBS electrodes during initial asleep DBS surgery can achieve sub-millimeter accuracy and MDS-UPDRS part III improvement comparable to cases that did not require repositioning. However, our small sample size limits definitive conclusions, demonstrating a need for larger studies to confirm these findings that support intraoperative imaging-based verification of electrode location.

Indexed as

deep brain stimulationelectrode repositioningmovement disordersstereotaxic techniquessurgical technique

Identifiers

PMID41210050
PMCPMC12591352

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.